5 itc mode – Rainbow Electronics ATMOS™ 1M60 User Manual

Page 9

Advertising
background image

9

5429B–IMAGE–04/05

[Preliminary] ATMOS -1M60/1M30

Therefore the minimum period is reduced to 1 × readout time. As the integration time is not the
same for all lines (in the following timing diagram line n integration time is greater than line 1
integration time) this mode must be used with a pulsed light source or a shutter element. More-
over any residual light when shutter output signal is inhibited must be avoided. The exposure
time is defined by the shutter time and all the lines are exposed during the same time.

See register Aperture Shutter Time @ 246H Internal Register Mapping on

page 15

Figure 4-4.

Triggered Mode Without Full Reset Chronogram

4.1.5

ITC Mode

Principle: An external sync controls both the integration time and the frame rate.

The trigger event initiates the following sequence:

• Stop of readout frame in progress and reset of readout pointer to line 1

• Shutter output signal is activated during a time defined by the high state of the ITC signal

• Readout of frame N. The readout data is forwarded to the CameraLink interface (FVAL

active) starting with the first line

Table 4-3.

Shutter Time Values at Triggered Mode without Full Reset

Label

Description

1M60

1M30

Tsh

Maximum shutter time (ms)

655

1310

T1

Step duration (µs)

10

20

Line1 Reset

Line 1

Integration

(Frame N)

Frame N

Readout

Line n

Integration

(Frame N)

Line n Reset

Line 1 Readout

and Reset

Trigger N Event

Trigger In

Programmable

Shutter Time

Shutter out

Trigger Delay

FVA

L

Line n Readout

and Reset