Rainbow Electronics DS1250Y_AB User Manual

Page 7

Advertising
background image

DS1250Y/AB

041497 7/11

POWER–DOWN/POWER–UP TIMING

(t

A

: See Note 10)

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

CE, WE at V

IH

before

Power–Down

t

PD

0

µ

s

11

V

CC

Slew from V

TP

to 0V

t

F

300

µ

s

V

CC

Slew from 0V to V

TP

t

R

300

µ

s

CE, WE at V

IH

after Power–Up

t

REC

2

125

ms

(t

A

= 25

°

C)

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

Expected Data Retention Time

t

DR

10

years

9

WARNING:

Under no circumstance are negative undershoots, of any amplitude, allowed when device is in battery backup mode.

NOTES:

1. WE is high for a Read Cycle.

2. OE = V

IH

or V

IL

. If OE = V

IH

during write cycle, the output buffers remain in a high impedance state.

3. t

WP

is specified as the logical AND of CE and WE. t

WP

is measured from the latter of CE or WE going low to the

earlier of CE or WE going high.

4. t

DH

, t

DS

are measured from the earlier of CE or WE going high.

5. These parameters are sampled with a 5 pF load and are not 100% tested.

6. If the CE low transition occurs simultaneously with or latter than the WE low transition, the output buffers remain

in a high impedance state during this period.

7. If the CE high transition occurs prior to or simultaneously with the WE high transition, the output buffers remain

in high impedance state during this period.

8. If WE is low or the WE low transition occurs prior to or simultaneously with the CE low transition, the output buffers

remain in a high impedance state during this period.

9. Each DS1250 has a built–in switch that disconnects the lithium source until V

CC

is first applied by the user. The

expected t

DR

is defined as accumulative time in the absence of V

CC

starting from the time power is first applied

by the user.

10. All AC and DC electrical characteristics are valid over the full operating temperature range. For commercial prod-

ucts, this range is 0

°

C to 70

°

C. For industrial products (IND), this range is –40

°

C to +85

°

C.

11. In a power–down condition the voltage on any pin may not exceed the voltage on V

CC

.

12. t

WR1

and t

DH1

are measured from WE going high.

13. t

WR2

and t

DH2

are measured from CE going high.

14. DS1250 DIP modules are recognized by Underwriters Laboratory (U.L.

) under file E99151. DS1250 PowerCap

modules are pending U.L. review. Contact the factory for status.

Advertising