Dc test conditions, Ac test conditions, Ordering information – Rainbow Electronics DS1250Y_AB User Manual

Page 8

Advertising
background image

A

1

DIM

MIN

MAX

A

IN.

MM

B

IN.

MM

C IN.

MM

D IN.

MM

E

IN.

MM

F

IN.

MM

G IN.

MM

H IN.

MM

J

IN.

MM

K

IN.

MM

1.680
42.67

1.700
43.18

0.720
18.29

0.740
18.80

0.355
9.02

0.375
9.52

0.080
2.03

0.110
2.79

0.015
0.38

0.025
0.63

0.120
3.05

0.160
4.06

0.090
2.29

0.110
2.79

0.590
14.99

0.630
16.00

0.008
0.20

0.012
0.30

0.015
0.38

0.021
0.53

C

F

G

K

D

H

B

E

J

32–PIN

PKG

DS1250Y/AB

041497 8/11

DC TEST CONDITIONS

Outputs Open
Cycle = 200 ns for operating current
All voltages are referenced to ground

AC TEST CONDITIONS

Output Load: 100 pF + 1TTL Gate
Input Pulse Levels: 0 – 3.0V
Timing Measurement Reference Levels

Input: 1.5V
Output: 1.5V

Input pulse Rise and Fall Times: 5 ns

ORDERING INFORMATION

DS1250 TTP– SSS – III

Operating Temperature Range
blank: 0

°

to 70

°

IND: –40

°

to +85

°

C

Access
70:
100:

Speed
70 ns
100 ns

Package Type
blank: 32–pin 600 mil DIP
P: 34–pin PowerCap Module

Device Type
AB:

±

5%

Y:

±

10%

DS1250Y/AB NONVOLATILE SRAM 32–PIN 740 MIL EXTENDED DIP MODULE