Table 9-2.

Valid SPRL and Global Protect/Unprotect Conditions

WP

State

Current

SPRL
Value

New Write Status

Register Byte 1

Data

Protection Operation

New

SPRL
Value

Bit

7 6 5 4 3 2 1 0

0

0

0 x 0 0 0 0 x x
0 x 0 0 0 1 x x

0 x 1 1 1 0 x x
0 x 1 1 1 1 x x

1 x 0 0 0 0 x x
1 x 0 0 0 1 x x

1 x 1 1 1 0 x x
1 x 1 1 1 1 x x

Global Unprotect – all Sector Protection Registers reset to 0
No change to current protection
No change to current protection
No change to current protection
Global Protect – all Sector Protection Registers set to 1

Global Unprotect – all Sector Protection Registers reset to 0
No change to current protection
No change to current protection
No change to current protection
Global Protect – all Sector Protection Registers set to 1

0
0
0
0
0

1
1
1
1
1

0

1

x x x x x x x x

No change to the current protection level. All sectors currently protected will remain protected
and all sectors currently unprotected will remain unprotected.

The Sector Protection Registers are hard-locked and cannot be changed when the WP pin is
LOW and the current state of SPRL is 1. Therefore, a Global Protect/Unprotect will not occur.
In addition, the SPRL bit cannot be changed (the WP pin must be HIGH in order to change
SPRL back to a 0).

1

0

0 x 0 0 0 0 x x
0 x 0 0 0 1 x x

0 x 1 1 1 0 x x
0 x 1 1 1 1 x x

1 x 0 0 0 0 x x
1 x 0 0 0 1 x x

1 x 1 1 1 0 x x
1 x 1 1 1 1 x x

Global Unprotect – all Sector Protection Registers reset to 0
No change to current protection
No change to current protection
No change to current protection
Global Protect – all Sector Protection Registers set to 1

Global Unprotect – all Sector Protection Registers reset to 0
No change to current protection
No change to current protection
No change to current protection
Global Protect – all Sector Protection Registers set to 1

0
0
0
0
0

1
1
1
1
1

1

1

0 x 0 0 0 0 x x
0 x 0 0 0 1 x x

0 x 1 1 1 0 x x
0 x 1 1 1 1 x x

1 x 0 0 0 0 x x
1 x 0 0 0 1 x x

1 x 1 1 1 0 x x
1 x 1 1 1 1 x x

No change to the current protection level. All sectors currently protected will remain
protected and all sectors currently unprotected will remain unprotected.

The Sector Protection Registers are soft-locked and cannot be changed when the
current state of SPRL is 1. Therefore, a Global Protect/Unprotect will not occur.
However, the SPRL bit can be changed back to a 0 from a 1 since the WP pin is
HIGH. To perform a Global Protect/Unprotect, the Write Status Register command
must be issued again after the SPRL bit has been changed from a 1 to a 0.

0
0
0
0
0

1
1
1
1
1