DC and AC Operating Conditions

Commercial

Industrial

Operating Temperature (Ambient)

0

°

C - 70

°

C

-40

°

C - 85

°

C

V

CC

(3.3V) Power Supply

3.0V

± 3.6%

3.0V

± 3.6%

DC Characteristics

Symbol

Parameter

Condition

Min

Typ

Max

Units

I

IL

Input or I/O Low
Leakage Current

V

IN

= V

CC

-2

-10

µA

I

IH

Input or I/O High
Leakage Current

2

10

I

OZ

Tri-state Output
Off-state Current

V

O

= V

CC

or GND

-40

40

µA

I

CC1

Power Supply Current, Standby

V

CC

= Max

V

IN

= 0, V

CC

Std Mode

Com.

40

mA

Ind.

45

mA

I

CC2

Power Supply Current,
Power-down Mode

V

CC

= Max

V

IN

= 0, V

CC

“PD” Mode

0.75

5.0

mA

I

CC3

(2)

Reduced-power Mode
Supply Current, Standby

V

CC

= Max

V

IN

= 0, V

CC

Std Mode

Com.

25

mA

Ind.

30

mA

V

IL

Input Low Voltage

-0.3

0.8

V

V

IH

Input High Voltage

2.0

V

CCINT

+ 0.3

V

V

OL

Output Low Voltage (TTL)

V

IN

= V

IH

or V

IL

V

CC

= MIN, I

OL

= 8 mA

Com.

0.45

V

Ind.

0.45

Output Low Voltage (CMOS)

V

IN

= V

IH

or V

IL

V

CC

= MIN, I

OL

= 0.1 mA

Com.

0.2

V

Ind.

0.2

V

V

OH

Output High Voltage (TTL)

V

IN

= V

IH

or V

IL

V

CC

= MIN, I

OH

= 2.0 mA

2.4

V

Output High Voltage (CMOS)

V

IN

= V

IH

or V

IL

V

CCIO

= MIN, I

OH

= -0.1 mA

V

CCIO

- 0.2

Advertising