5 report requests – Rainbow Electronics AT42QT1110-AZ User Manual

Page 12

Advertising
background image

12

9570H–AT42–02/10

AT42QT1110-MZ/AT42QT1110-AZ

Figure 4-2.

Sleep Command – CRC Enabled

When the “Send Setups” command is received, the QT1110 stops measurement of QTouch
sensors and waits for 42 bytes of data to be sent. Only when all 42 bytes have been received
(and the CRC byte, if CRC is enabled), the QT1110 applies all the settings to RAM and resumes
measurement. In this case, if CRC is enabled, the CRC byte is calculated for all the data sent by
the host, including the command byte 0x01.

Control Commands are specified in detail in

Section 5 on page 22

.

4.1.5

Report Requests

Report Requests are sent by the Host to instruct the QT1110 to return status information. The
host sends the appropiate “Report Request” command, then transmits Null bytes on MOSI while
the QT1110 returns the report data on MISO.

Figure 4-3.

All Keys Report – CRC Disabled

Host (Sends on MOSI)

Command: 0x05

Simultaneous

Transmission

Command CRC: 0x3F

Response: 0x3F (Expected Command CRC)

Response: 0x55 ( Idle”

Fresh Command)

Device (Responds on MISO)

Host (Sends on MOSI)

Command: 0xC1

Device (Responds on MISO)

Null: 0x00

Key Status Report Byte 0

Null: 0x00

Key Status Report Byte 1

Simultaneous

Transmission

Response: 0x55 ( Idle”

Fresh Command)

Advertising