AT42QT1110-MZ/AT42QT1110-AZ

4.1.5.2

Get Instructions

Get instructions are instructions that read the data from a location in the QT1110 memory map.

Figure 4-7.

Positive Recalibration Delay Get Instruction – CRC Disabled

The host sends the appropriate “Get” command, followed by a “Null” byte. The QT1110 returns
the contents of the addressed memory location.

Figure 4-7 on page 15

shows the exchange for a report on the positive recalibration delay

(assuming that the data byte is 0x0C).

With CRC Enabled, this exchange takes 4 bytes, with a command CRC transmitted by the host
and a report CRC returned by the QT1110 (see

Figure 4-8

).

Figure 4-8.

Positive Recalibration Delay Get Instruction – CRC Enabled

Host (Sends on MOSI)

Command: 0xD5

Null: 0x00

“Get” Data: 0x0C (Positive Recalibration Delay)

Simultaneous

Transmission

Response: 0x55 ( Idle”

Fresh Command)

Device (Responds on MISO)

Host (Sends on MOSI)

Command: 0xD5

Null: 0x00

Null: 0x00

“Get” CRC: 0xA3

Simultaneous

Transmission

Command CRC: 0x68

Response: 0x68 (Expected Command CRC)

“Get” Data: 0x0C (Positive Recalibration Delay)

Response: 0x55 ( Idle”

Fresh Command)

Device (Responds on MISO)