DS1644/DS1644P

7 of 11

AC ELECTRICAL CHARACTERISTICS

(Over the Operating Range)

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

Read Cycle Time

t

RC

120

ns

Address Access Time

t

AA

120

ns

CE

Access Time

t

CEA

120

ns

CE

Data Off Time

t

CEZ

40

ns

Output Enable Access Time

t

OEA

100

ns

Output Enable Data Off Time

t

OEZ

40

ns

Output Enable to DQ Low-Z

t

OEL

5

ns

CE

to DQ Low-Z

t

CEL

5

ns

Output Hold from Address

t

OH

5

ns

Write Cycle Time

t

WC

120

ns

Address Setup Time

t

AS

0

ns

CE

Pulse Width

t

CEW

100

ns

Address Hold from End of Write

t

AH1

t

AH2

5

30

ns
ns

5
6

Write Pulse Width

t

WEW

75

ns

WE

Data Off Time

t

WEZ

40

ns

WE

or

CE

Inactive Time

t

WR

10

ns

Data Setup Time

t

DS

85

ns

Data Hold Time High

t

DH1

t

DH2

0

15

ns
ns

5
6

AC TEST CONDITIONS

Input Levels:

0V to 3V

Transition Times:

5 ns

CAPACITANCE (t

A

= 25

°

C)

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

Capacitance on all pins (except DQ)

C

I

7

pF

Capacitance on DQ pins

C

DQ

10

pF

AC ELECTRICAL CHARACTERISTICS
(POWER-UP/DOWN TIMING)

(Over the Operating Range)

PARAMETER

SYMBOL

MIN

TYP

MAX

UNITS

NOTES

CE

or

WE

at V

IH

before Power Down

t

PD

0

µ

s

V

PF

(Max) to V

PF

(Min) V

CC

Fall Time

t

F

300

µ

s

V

PF

(Min) to V

SO

V

CC

Fall Time

t

FB

10

µ

s

V

SO

to V

PF

(Min) V

CC

Rise Time

t

RB

1

µ

s

V

PF

(Min) to V

PF

(Max) V

CC

Rise Time

t

R

0

µ

s

Power-Up

t

REC

15

35

ms

Expected Data Retention Time
(Oscillator On)

t

DR

10

years

4