Clock oscillator control, Reading the clock – Rainbow Electronics DS1554 User Manual

Page 6

Advertising
background image

DS1554

6 of 20

DS1554 REGISTER MAP Table 2

DATA

ADDRESS

B

7

B

6

B

5

B

4

B

3

B

2

B

1

B

0

FUNCTION/RANGE

7FFFh

10 Year

YEAR

YEAR

00-99

7FFEh

X

X

X

10 M

MONTH

MONTH

01-12

7FFDh

X

X

10 Date

DATE

DATE

01-31

7FFCh

X

FT

X

X

X

DAY

DAY

01-07

7FFBh

X

X

10 HOUR

HOUR

HOUR

00-23

7FFAh

X

10 MINUTES

MINUTES

MINUTES

00-59

7FF9h

OSC

10 SECONDS

SECONDS

SECONDS

00-59

7FF8h

W

R

10 CENTURY

CENTURY

CONTROL

00-39

7FF7h

WDS

BMB4

BMB3

BMB2

BMB1

BMB0

RB1

RB0

WATCHDOG

7FF6h

AE

Y

ABE

Y

Y

Y

Y

Y

INTERRUPTS

7FF5h

AM4

Y

10 DATE

DATE

ALARM DATE

01-31

7FF4h

AM3

Y

10 HOURS

HOURS

ALARM HOURS

00-23

7FF3h

AM2

10 MINUTES

MINUTES

ALARM MINUTES

00-59

7FF2h

AM1

10 SECONDS

SECONDS

ALARM SECONDS

00-59

7FF1h

Y

Y

Y

Y

Y

Y

Y

Y

UNUSED

7FF0h

WF

AF

0

BLF

0

0

0

0

FLAGS

X = Unused, read/writeable under Write and Read

AE = Alarm Flag Enable

bit control

Y = Unused, read/writeable without Write and Read

FT = Frequency Test bit

bit control

OSC

= Oscillator start/stop bit

ABE = Alarm in battery Back-up mode enable

W = Write bit

AM1-AM4 = Alarm Mask bits

R = Read bit

WF = Watchdog Flag

WDS = Watchdog Steering bit

AF = Alarm Flag

BMB0-BMB4 = Watchdog Multiplier bits

0 = 0 and are read only

RB0-RB1 = Watchdog Resolution bits

BLF = Battery Low Flag

CLOCK OSCILLATOR CONTROL

The Clock oscillator may be stopped at any time. To increase the shelf life of the backup lithium battery
source, the oscillator can be turned off to minimize current drain from the battery. The

OSC

bit is the

MSB of the Seconds Register (B7 of 7FF9h). Setting it to a 1 stops the oscillator, setting to a 0 starts the
oscillator. The DS1554 is shipped from Dallas Semiconductor with the clock oscillator turned off,

OSC

bit set to a 1.

READING THE CLOCK

When reading the RTC data, it is recommended to halt updates to the external set of double-buffered RTC
Registers. This puts the external registers into a static state allowing data to be read without register
values changing during the read process. Normal updates to the internal registers continue while in this
state. External updates are halted when a 1 is written into the read bit, B6 of the Control Register (7FF8h).
As long as a 1 remains in the Control Register read bit, updating is halted. After a halt is issued, the
registers reflect the RTC count (day, date, and time) that was current at the moment the halt command
was issued. Normal updates to the external set of registers will resume within 1 second after the read bit is
set to a 0 for a minimum of 500

µ

s. The read bit must be a zero for a minimum of 500

µ

s to ensure the

external registers will be updated.