Configuration register bit descriptions table 5 – Rainbow Electronics DS1631 User Manual

Page 6

Advertising
background image

DS1631

6 of 14

CONFIGURATION REGISTER BIT DESCRIPTIONS Table 5

BIT NAME

(USER ACCESS)

FUNCTIONAL DESCRIPTION

DONE—Temperature
Conversion Done
(Read Only)

Power-up/POR state = 1
DONE = 0—Temperature conversion is in progress.
DONE = 1—Temperature conversion is complete.

THF—Temperature High Flag
(Read/Write)

Power-up/POR state = 0.
THF = 0—The measured temperature has not exceeded the value
stored in the T

H

register since power-up.

THF = 1—At some point since power-up the measured temperature
has been higher than the value stored in the T

H

register. THF will

remain a 1 until it is over-written with a 0 by the user or until the
power is cycled.

TLF—Temperature Low Flag
(Read/Write)

Power-up/POR state = 0
TLF = 0—The measured temperature has not been lower than the
value stored in the T

L

register since power-up.

TLF = 1—At some point since power-up the measured temperature
has been lower than the value stored in the T

L

register. TLF will

remain a 1 until it is over-written with a 0 by the user or until the
power is cycled.

NVB—NV Memory
Busy
(Read Only)

Power-up/POR state = 0
NVB = 1—A write to EEPROM

memory is in progress

NVB = 0—NV memory is not busy.

R1—Resolution Bit 1
(Read/Write)

Power-up/POR state = 1
Used to set conversion, T

H

, and T

L

resolution (see Table 4)

R0—Resolution Bit 0
(Read/Write)

Power-up/POR state = 1
Used to set conversion, T

H

, and T

L

resolution (see Table 4)

POL*— T

OUT

Polarity

(Read/Write)

Power-up/POR state = last value written to this bit
POL = 1—T

OUT

is active high.

POL = 0—T

OUT

is active low.

1SHOT*— Conversion Mode
(Read/Write)

Power-up/POR state = last value written to this bit
1SHOT = 1—One-shot mode. The Start Convert T command will
cause a single temperature conversion and then the device will return
to a low-power standby state.
1SHOT = 0—Continuous conversion mode. The Start Convert T
command will initiate continuous temperature conversions.

*Stored in EEPROM