Ds1870 ldmos rf power-amplifier bias controller, Application information, Typical operating circuit – Rainbow Electronics DS1870 User Manual

Page 27: Power-supply decoupling

Advertising
background image

DS1870

LDMOS RF Power-Amplifier Bias

Controller

____________________________________________________________________

27

See Figure 5 for a read example using the repeated
start condition to specify the starting memory location.

Reading multiple bytes from a slave: The read opera-
tion can be used to read multiple bytes with a single
transfer. When reading bytes from the slave, the master
simply ACKs the data byte if it desires to read another
byte before terminating the transaction. After the master
reads the last byte it NACKs to indicate the end of the
transfer and generates a stop condition. This can be
done with or without modifying the address counter’s
location before the read cycle. The DS1870’s address
counter does not wrap on page boundaries during read

operations, but the counter will roll from its upper most
memory address FFh to 00h if the last memory location
is read during the read transaction.

Application Information

Power-Supply Decoupling

To achieve best results, it is recommended that the power
supply is decoupled with a 0.01µF or a 0.1µF capacitor.
Use high-quality, ceramic, surface-mount capacitors, and
mount the capacitors as close as possible to the V

CC

and

GND pins to minimize lead inductance.

SDA

SCL

A2

A1

A0

FAULT

V

CC

GND

5V

5V REFERENCE

R

POT1

R

POT2

R

S2

R

S1

49.9kΩ

4.22kΩ

RF

POWER

AMP

RF

IN

RF

OUT

W

1

L

1

W

2

H

COM

L

2

N.C.

N.C.

N.C.

N.C.

4.7kΩ

3 PLACES

28V

I

D1

I

D2

V

D

FACTORY-CALIBRATED 13-BIT ADC

(CUSTOMER ADJUSTABLE FULL-

SCALE AND OFFSET VALUES)

NOTES:
1) IN THIS CONFIGURATION, THE VOLTAGE RANGE OF W

1

AND W

2

IS

3V-5V. THIS RANGE CAN BE EXTENDED USING EXTERNAL RESISTORS.
2) ONE MAX6156B CAN BE USED WITH MULTIPLE DS1870s.

DS1870

MAX6165B

Typical Operating Circuit

Advertising