ADIS16250/ADIS16255

Rev. B | Page 13 of 20

PROGRAMMING AND CONTROL

CONTROL REGISTER OVERVIEW

The ADIS16250/ADIS16255 offer many programmable features
controlled by writing commands to the appropriate control
registers using the SPI. Table 8 provides a summary of these
control registers, which controls the operation of the following
parameters:

• Calibration
• Global commands
• Operational control

Sample rate

Power management

Digital filtering

Dynamic range

DAC output

Digital I/O

• Operational status and diagnostics

Self-test

Status conditions

Alarms

CONTROL REGISTER STRUCTURE

The ADIS16250/ADIS16255 uses a temporary, RAM-based
memory structure to facilitate the control registers displayed in
Table 8. The start-up configuration is stored in a flash memory
structure that automatically loads into the control registers
during the start-up sequence. Each nonvolatile register has a
corresponding flash memory location, for storing the latest
configuration contents. Since flash memory has endurance
limitations, the contents of each nonvolatile register must be
manually stored to flash (note that the contents of the control
register contents are only nonvolatile when they are stored to
flash). The manual flash update command, made available
in the COMMAND register, provides this function. The
ENDURANCE register provides a counter that allows for
memory reliability management against the 20,000-write cycle
specification.

Table 8. Control Register Memory Map
Register

Name Type Volatility

Address

Bytes Function

Reference

Table

GYRO_OFF R/W

Nonvolatile

0x15,

0x14 2

Gyroscope bias offset factor

Table 9, Table 10

GYRO_SCALE R/W

Nonvolatile 0x17,

0x16

2

Gyroscope scale factor

Table 11, Table 12

0x18 to 0x1F

8

Reserved

ALM_MAG1 R/W

Nonvolatile

0x21,

0x20 2 Alarm 1 amplitude threshold and polarity

Table 31, Table 32

ALM_MAG2 R/W

Nonvolatile

0x23,

0x22 2 Alarm 2 amplitude threshold and polarity

Table 35, Table 36

ALM_SMPL1 R/W

Nonvolatile 0x25,

0x24

2

Alarm 1 sample period

Table 33, Table 34

ALM_SMPL2 R/W

Nonvolatile 0x27,

0x26

2

Alarm 2 sample period

Table 37, Table 38

ALM_CTRL R/W

Nonvolatile

0x29,

0x28 2 Alarm

control

register

Table 39, Table 40

0x2A to 0x2F

6

Reserved

AUX_DAC

R/W

Volatile

0x31, 0x30

2

Auxiliary DAC data

Table 21, Table 22

GPIO_CTRL

R/W

Volatile

0x33, 0x32

2

Auxiliary digital I/O control register

Table 23, Table 24

MSC_CTRL R/W

Nonvolatile

1

0x35, 0x34

2

Miscellaneous control register

Table 26, Table 27

SMPL_PRD

R/W

Nonvolatile

0x37, 0x36

2

ADC sample period control

Table 15, Table 16

SENS/AVG R/W

Nonvolatile

0x39,

0x38 2 Defines the dynamic range (sensitivity setting)

and the number of taps for the digital filter

Table 19, Table 20

SLP_CNT R/W

Volatile 0x3B,

0x3A

2

Counter used to determine length of power-
down mode

Table 17, Table 18

STATUS

R

Volatile

0x3D, 0x3C

2

System status register

Table 28, Table 29

COMMAND

W

N/A

0x3F, 0x3E

2

System command register

Table 13, Table 14

1

The contents of the upper byte are nonvolatile; the contents of the lower byte are volatile.