Rmmr, Regis, Sa6code – Rainbow Electronics DS26519 User Manual

Page 176

Advertising
background image

DS26519 16-Port T1/E1/J1 Transceiver

176 of 310

Register Name:

Sa6CODE

Register Description:

Received Sa6 Codeword Register

Register Address:

06Fh + (200h x (n - 1)) + (2000h x [(n - 1) / 8]): where n = 1 to 16


Bit

#

7 6 5 4 3 2 1 0

Name

— — — —

Sa6n

Sa6n

Sa6n

Sa6n

Default

0 0 0 0 0 0 0 0

This register will report the received Sa6 codeword per ETS 300 233. The bits are monitored on a submultiframe
asynchronous basis, so the pattern reported could be one of multiple patterns that would represent a valid
codeword. The table below indicates which patterns reported in this register correspond to a given valid Sa6
codeword.

Bits 3 to 0: Sa6 Codeword Bit (Sa6n)

VALID Sa6 CODE

POSSIBLE REPORTED

PATTERNS

Sa6_8

1000, 0100, 0010, 0001

Sa6_A 1010,

0101

Sa6_C

110, 0110, 0011, 1001

Sa6_E

1110, 0111, 1011, 1101

Sa6_F 1111



Register Name:

RMMR

Register Description:

Receive Master Mode Register

Register Address:

080h + (200h x (n - 1)) + (2000h x [(n - 1) / 8]): where n = 1 to 16


Bit

# 7 6 5 4 3 2 1 0

Name

FRM_EN

INIT_DONE

— — — —

SFTRST

T1/E1

Default

0 0 0 0 0 0 0 0


Bit 7: Framer Enable (FRM_EN). This bit must be set to the desired state before writing INIT_DONE.

0 = Framer disabled—held in low-power state.

1 = Framer enabled—all features active.


Bit 6: Initialization Done (INIT_DONE). The user must set this bit once he has written the configuration registers.
The host is required to write or clear all device registers prior to setting this bit. Once INIT_DONE is set, the
DS26519 will check the FRM_EN bit and, if enabled, will begin operation based on the initial configuration.

Bit 1: Soft Reset (SFTRST). Level sensitive “soft” reset. Should be taken high, then low to reset the receiver.

0 = Normal operation.
1 = Reset the receiver.

Note: This reset does not clear the registers.

Bit 0: Receiver T1/E1 Mode Select (T1/E1). Sets operating mode for receiver only! This bit must be set to the
desired state before writing INIT_DONE.

0 = T1 operation.
1 = E1 operation.