background image

DS26519 16-Port T1/E1/J1 Transceiver

178 of 310

Register Name:

RCR1 (E1 Mode)

Register Description:

Receive Control Register 1

Register Address:

081h + (200h x (n - 1)) + (2000h x [(n - 1) / 8]): where n = 1 to 16


Bit

# 7 6 5 4 3 2 1 0

Name

— RHDB3

RSIGM

RG802

RCRC4 FRC SYNCE

RESYNC

Default

0 0 0 0 0 0 0 0

Note: This register has an alternate definition for T1 mode. See

RCR1

.


Bit 6: Receive HDB3 Enable (RHDB3)

0 = HDB3 disabled.
1 = HDB3 enabled (decoded per O.162).

Bit 5: Receive Signaling Mode Select (RSIGM)

0 = CAS signaling mode.
1 = CCS signaling mode.

Bit 4: Receive G.802 Enable (RG802). See

Figure 11-30

for details.

0 = Do not force RCHBLKn high during bit 1 of time slot 26.
1 = Force RCHBLKn high during bit 1 of time slot 26.

Bit 3: Receive CRC-4 Enable (RCRC4)

0 = CRC-4 disabled.
1 = CRC-4 enabled.

Bit 2: Frame Resync Criteria (FRC)

0 = Resync if FAS received in error three consecutive times.
1 = Resync if FAS or bit 2 of non-FAS is received in error three consecutive times.

Bit 1: Sync Enable (SYNCE)

0 = Auto resync enabled.
1 = Auto resync disabled.

Bit 0: Resynchronize (RESYNC). When toggled from low to high, a resynchronization of the receive-side framer is
initiated. Must be cleared and set again for a subsequent resync.