15

11050A–PMAAC–07-Apr-10

AT73C246

Notes: 1. Current consumption without load. One DCDC converter ON, the other one OFF.

2. Default output voltage are set during manufacturing. Please contact Atmel for other default settings.
3. Threshold levels are programmed in register PMU_RST_LVL (0x04)

OCP

Over-Current Protection

Output current.

1

1.4

1.8

A

T

START

Start-up Time

From OFF to PWM operation.
V

DD(0,1)

rising to 95% of final value.

5

ms

T

PWM

PFM to PWM Settling Time

No output load.

10

µs

PWRF

DET

Power Fail Detector Threshold
Accuracy

Overload of the programmed
threshold by 10mV / 5us min

(3)

.

-1

-

+1

%.V

DD

C

OUT

Total Capacitive Load

At V

FB{0,1}

pins.

8

36

µF

Table 9-5.