Sequence a sequence b, Table 11-7. hrst state timing table from run state, Symbol parameter comments min typ max units t – Rainbow Electronics AT73C246 User Manual

Page 35: Vddx shutdown time vddx is off in run state, Vdd4 shutdown time vdd4 is off in run st ate

Advertising
background image

35

11050A–PMAAC–07-Apr-10

AT73C246

Figure 11-8. AT73C246 - HRST state Supplies Shutdown timing diagram.

Note:

1. VDDx activity during RUN state is set by Bit7 of register VDDx_CTRL

Notes: 1. VDDx activity during STANDBY state is set by register PMU_STANDBY_SUPPLIES.

2. VDD4 activity during RUN state is set by Bit7 of register VDD4_CTRL.

Table 11-7.

HRST state timing table from RUN STATE

Symbol

Parameter

Comments

Min

Typ

Max

Units

T

HRST

HRST Event Detection Time

58

62

66

µs

T

OFF_AUDIO

Audio CODEC Shutdown Time

Audio CODEC is ON

486

512

538

ms

Audio CODEC is OFF

58

62

66

µs

T

OFF_VDDx

VDDx SHUTDOWN Time

VDDx is OFF in RUN state

(1)

58

62

66

µs

VDDx is ON in RUN state

(1)

4.8

5.2

5.4

ms

T

OFF_PMU

PMU Functions Shutdown Time

1.4

1.5

1.6

ms

Table 11-8.

HRST state timing table from STANDBY STATE

Symbol

Parameter

Comments

Min

Typ

Max

Units

T

HRST

HRST Event Detection
Time

58

62

66

µs

T

OFF_AUDIO

Audio CODEC Shutdown
Time

Audio CODEC is ON

486

512

538

ms

Audio CODEC is OFF

58

62

66

µs

T

OFF_VDDx

VDDx SHUTDOWN Time

VDDx is OFF during STANDBY state

(1)

58

62

66

µs

VDDx is ON during STANDBY state

(1)

4.8

5.2

5.4

ms

T

OFF_VDD4

VDD4 SHUTDOWN Time

VDD4 is OFF in RUN state

(2)

58

62

66

µs

VDD4 is ON in RUN state

(2)

4.8

5.2

5.4

ms

T

OFF_PMU

PMU Functions Shutdown
Time

1.4

1.5

1.6

ms

RUN / STANDBY /
POWERDOWN

STATE

SUPPLIES SHUTDOWN

HRST_EVENT

EVENT

HRST

STATE

T

HRST

T

OFF_VDD3

T

OFF_AUDIO

V

DD3

(3.3V)

V

DD1

(1.2V)

V

DD2

(1V)

3.3V

1.2V

1.85V

1V

RSTB

V

DD0

(1.85V)

T

OFF_VDD1

T

OFF_VDD0

T

OFF_VDD2

PMU FUNCTIONS
(LDO4, ADC, LED,...)

T

OFF_PMU

RUN / STANDBY /
POWERDOWN

STATE

SUPPLIES SHUTDOWN

HRST_EVENT

EVENT

HRST

STATE

T

HRST

T

OFF_VDD2

T

OFF_AUDIO

V

DD2

(1V)

V

DD1

(1.2V)

V

DD3

(3.3V)

1V

1.2V

1.85V

3.3V

RSTB

V

DD0

(1.85V)

T

OFF_VDD1

T

OFF_VDD0

T

OFF_VDD3

PMU FUNCTIONS
(LDO4, ADC, LED,...)

T

OFF_PMU

SEQUENCE A

SEQUENCE B

Advertising