When RUN state is reached from the POWERDOWN state, the power supplies are sequentially
started-up according to the

Figure 11-5

Figure 11-5. AT73C246 - POWERDOWN to RUN state Supplies Start-Up timing diagram..

Table 11-4.

POWERDOWN to RUN state timing table

Symbol

Parameter

Comments

Min

Typ

Max

Units

T

ON_SYS

POWER-ON Event Detection Time

1.7

1.8

1.9

ms

T

ON_VDD0

VDD0 Start-up Time

5

5.3

5.6

ms

T

ON_VDD1

VDD1 Start-up Time

5

5.3

5.6

ms

T

ON_VDD2

VDD2 Start-up Time

5.2

5.5

5.8

ms

T

ON_VDD3

VDD3 Start-up Time

5.2

5.5

5.8

ms

T

RESET

All Regulators ON To RSTB High

30.4

32

33.6

ms

POWERDOWN

STATE

SUPPLIES START UP

T

ON_SYS

RUN STATE

VDD3 (3.3V)

T

ON_VDD3

VDD0 (1.85V)

T

ON_VDD0

VDD1 (1.2V)

T

ON_VDD1

VDD2 (1V)

3.3V

1.85V

1.2V

1V

T

ON_VDD2

RSTB

VPAD LEVEL

T

RESET

PWREN

EVENT

SEQUENCE A

SEQUENCE B

POWERDOWN

STATE

SUPPLIES START UP

T

ON_SYS

RUN STATE

VDD2 (1V)

T

ON_VDD2

VDD0 (1.85V)

T

ON_VDD0

VDD1 (1.2V)

T

ON_VDD1

VDD3 (3.3V)

1V

1.85V

1.2V

3.3V

T

ON_VDD3

RSTB

VPAD LEVEL

T

RESET

PWREN

EVENT