Installation to Concrete Ceilings or Concrete/Cinder Block Walls

• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to con-

crete covered with plaster, drywall, or other fi nishing
material. If mounting to concrete surfaces covered
with a fi nishing surface is unavoidable, the fi nishing
surface must be counterbored as shown below. Be
sure concrete anchors do not pull away from con-
crete when tightening screws. If plaster/drywall is
thicker than 5/8" (16 mm), custom fasteners must be
supplied by installer (not UL approved).

WARNING

NOTE: Wall installation with models EXC, EXC-S
and EXC-W is not available.

Place ceiling/wall plate (A) on ceiling or wall as a
template. Note: Place ceiling/wall plate according
to position of opening in outer channel (B) as shown
in fi gure 2.4. or fi gure 2.5. Drill two 1/4" (6 mm) dia.
holes to a minimum depth of 2.5" (64 mm). Attach
ceiling/wall plate (A) using two concrete anchors (J),
two #14 x 2.5" wood screws (H) and two washers (O)
as shown in fi gure 2.6. Tighten wood screws (H) until
ceiling/wall plate (A) is fi rmly attached.

CUT

A

W

A

Y

VIEW

INCORRECT

concrete

plaster/
dry wall

CORRECT

concrete

plaster/
dry wall

• Tighten wood screws fi rmly, but do not overtighten.

Overtightening can damage the screws, greatly
reducing their holding power.

• Never tighten in excess of 80 in • lb (9 N.M.).

WARNING

2

A

A

concrete
surface

1

3

2

J

Drill holes and insert anchors (J).

Place plate (A) over anchors (J) and secure with washers (O)
and screws (H).

Tighten all fasteners.

A

J

H

• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete

thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifi ca-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Installer must verify that the supporting surface will safely support the combined load of the equipment and all at-

tached hardware and components.

WARNING

J

B

A

H

H

B

A

J

OPENING ON OUTER
CHANNEL (B) INDICATES
FRONT OF MOUNT

CONCRETE
CEILING

CONCRETE
WALL

CINDER
BLOCK
WALL

OPENING ON
OUTER CHANNEL
(B) INDICATES TOP
OF MOUNT

fi g. 2.4

fi g. 2.5

fi g.
2.6

CEILING
INSTALLATION

WALL INSTALLATION

(EXCEPT FOR
EXC MODELS)

O

O

O