1 description of the inverter, 1 connections, 2 technical characteristics – R&M Materials Handling VARIABLE SPEED CONTROLS CMXC 007 Service Manual User Manual

Page 3

Advertising
background image

R&M Materials Handling, Inc.

4501 Gateway Boulevard

Springfield, Ohio 45502

P.: (937) 328-5100

FAX: (937) 325-5319

3/9

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

1 DESCRIPTION OF THE INVERTER

There are high voltages inside the inverter (including the programming switches).
Wait for at least three minutes after the supply voltage has been switched off before
any service actions.

DMCS007

c_fcmo1b

1. Terminal X1

2. Red led (fault)

3. Green led (ok)

4. Programming switches

1.1

Connections

All connections are made to terminal block X1 as follows:

Crane power supply conductor rail must have double collectors.

DMCS007

Nbr

Name

Description

1

PE

Protective earth.

2

L1

Mains, phase 1. 380-480V 50/60Hz.

3

L2

Mains, phase 2. 380-480V 50/60Hz.

4

L3

Mains, phase 3. 380-480V 50/60Hz.

5

U

Motor, phase 1.

6

V

Motor, phase 2.

7

W

Motor, phase 3.

8

S1

Drive command. Direction 1. 48 or 115V 50/60Hz

9

S2

Drive command. Direction 2. 48 or 115V 50/60Hz

10

SP2/AP

Speed 2 / Acceleration command. 48 or 115V 50/60Hz

11

ON

Control voltage, neutral.

Standard duty resistor must be disconnected when heavy duty resistor DMHR01F90
is connected to terminals R+ and R

−−−−

.

1.2

Technical characteristics

Technical data

DMCS007

Power range

0.75kW

Supply voltage

380 - 480 VAC -10%/+5%

Nominal supply frequency

48 – 62 Hz

Nominal current

2.4A

Digital control

S1, S2, DI3

Max output voltage

Equal to supply voltage

Control voltage range

48 VAC/115 +/- 10%. If control voltage is 230VAC, front resistors (15k,2W) have to be
connected to digital inputs

Output

Ambient temperature

-10

o

C to 50

o

C

Advertising