2 DESCRIPTION OF CONTROL MODES

2.1

MS2-control (S4-1=OFF)

c_coms2a

A. Push button position

B. Speed

S1 means “drive minimum speed forward”
S2 means “drive minimum speed reverse”
SP2 means “maximum speed”
When S1 and S2 or are not active the inverter decelerates to zero

2.2

EP2-control (S4-1=ON)

c_coep2a


A. Push button position
B. Speed
0. Decelerate
1. Maintain speed
2. Accelerate

S1 means “drive forward”
S2 means “drive reverse”
AP means “acceleration”
When starting S1 and S2 mean “accelerate to minimum speed”
When S1 and S2 are not active the inverter decelerates to zero
During running S1 and S2 mean “hold speed”
At maximum speed AP means “hold speed”