Switch S3

Acceleration/deceleration

-1

-2

-3

-4

ramp time

0

1

0

1

8.0 sec

4.2

Selection of the motor type

The motor type is selected by switches S4-2, S4-3 and S4-4. There are several motor dependant parameters which
are set according to the selected motor (i.e. the operator selects a parameter set). The MF06-motors are selected
as follows:

S4

Motor type

Nominal frequency

Nominal power

-2

-3

-4

0

0

0

MF06MA200

100Hz (120Hz)

0.3kW (0.37kW)

1

0

0

MF06MA100

80Hz

0.65kW

0

1

0

MF06LA200

100Hz (120Hz)

0.45kW (0.55kW)

1

1

0

MF06LA100

80Hz

0.65kW

0

0

1

2*MF06MA200

100Hz (120Hz)

2*0.3kW (2*0.37kW)

1

0

1

MF06L-200

35 Hz

0.15kW