Quick install procedure – Crown Audio IQ-USM 810 User Manual

Page 5

Advertising
background image

Page 5

IQ-USM 810 IQ Digital Processor / Digital Mixer

IQ-USM 810 Reference Manual

Quick Install Procedure

This procedure is provided for those who are already familiar with Crown’s
IQ System and would like to install the IQ-USM 810 in the shortest time
possible. Less experienced installers or those wishing a full explanation of
the installation procedure are encouraged to refer to Section 3.

Prepare the IQ-USM 810:

1 Set the IQ address (Section 3.2.1) on the IQ-USM 810 to an unused

IQ address.

2 If the unit is to be used as a system interface, set the baud rate, and

set the unit to act as system interface (green Interface LED on).

Mounting:

3 Mount the unit into a standard 19-inch (48.3-cm) equipment rack or

cabinet, or it can be stacked.

Install the wiring:

4 Connect the IQ-USM 810 to the IQ System via the IQ Bus, or directly

to the host computer if the unit is to be used as the system interface
or stand-alone (see Section 3.1).

5 Turn off all amplifiers or other equipment that will either feed or be

connected to the unit

.

6 Connect the audio wiring to the IQ-USM 810 inputs and outputs.

7 Connect the IQ Bus wiring to all components if the unit is to be used

as the system interface (see Section 3.2.2).

8 Connect any circuits to be used with the Control Port connector to

the unit.

9 Connect the unit to the AC receptacle.

Prepare the audio system:

10 Set all equipment that will be in the signal chain before or after the

IQ-USM 810.

11 Set and verify all level and gain settings on all amplifiers or other

equipment that will either feed or be connected to the unit

.

Configure the IQ-USM 810:

12 Set input selector switches for Mic, Line, or Phantom, depending

upon input signal to be fed to the input.

13 Set gain levels on the back of the unit.