Reference Manual

IQ–P.I.P.-MEM Programmable Input Processor for IQ Systems

Fig. 4.8 Amplifier Scale Factor Values

and Output Signal Pad Settings

Multiloop Advantages

• A break in communication

in one loop does not affect
other loops.

• Over 250 IQ components of

the same type can be used
in a system.

• The same IQ address can

be used more than once
(once per loop per model).

Single Loop Advantages (with
IQ-INT II interfaces)

• The IQ System can send

and retrieve data faster in a
single loop.

• “Real time” level display of

a greater number of units is
possible.

The IQ–P.I.P.-MEM can be
connected to the Crown Bus with
inexpensive twisted-pair wiring

4.6 A Closer Look at Crown

Bus Wiring

The IQ–P.I.P.-MEM must be con-
nected to a Crown Bus loop having
an IQ2-compatible IQ interface in
order for the IQ System to control
or monitor it. The Crown Bus is a
serial communication loop de-
signed to transmit IQ commands
and data. As implemented in the
IQ–P.I.P.-MEM, it is a 20 milliamp
current loop operating at a BAUD
rate of 38.4 K. The loop must be
unbroken.

If the system includes an IQ–INT II
inter face, it can accept eight
different Crown Bus loops or zones.