2. Electrical characteristics


2.1 Absolute maximum ratings

Ratings Min

Max

Unit

Storage Temperature

-40

+85

°C

Operating Temperature

-40

+85

°C

Supply voltage

PVCC

-0.4

3.6

V

+3V3 -0.4

3.6

V

Other terminal voltages

GND – 0.4

+3V3 +0.4

V

Table 2-1 Absolute maximum ratings

2.2 Recommended operating conditions

Ratings Min

Typ

Max

Unit

Operating Temperature

-40

25

+85

°C

Supply

voltage

PVCC

2.7 3.3 3.6 V

+3V3

2.7 3.3 3.6 V

UART

3.0 3.3 3.6 V

USB

3.1 3.3 3.6 V

Table 2-2 Recommended operating conditions

2.3 Power Consumptions

Role Operation

Mode

UART

Rate(kbps)

Current Unit

-

Inquiry and page Scan

115.2

76

mA

-

Power on (Standby)

115.2

2

mA

Connectable

Mode(Mode3)

115.2

18 mA

Connected (No data)

115.2-

15

mA

Connected (file transfer)

115.2

45

mA

Connected (file transfer)

9.6

55

mA

Table 2-3 Power consumptions