supported by the LS100M. Hardware flow control method controls data communication flow by

sending signals back and forth between two connected devices.

The purpose of the DTR/DSR pin is to emulate modem signal control or to c ontrol TCP connection

state by using serial port signal. The DTR is a write-only output signal, whereas the DSR is a read-only

input signal in the LS100M side.

The DTR option can be set to one of three types: always high, always low or show TCP connection. If

the DTR behavior is set to show TCP connection, the state of the DTR pin will be maintained high if

the TCP connection is established.

The DSR option can be set to one of three types: none, allow TCP connection only by high or

open/close TCP connection. Allow TCP connection only by HIGH is valid only if host mode is TCP

server or equivalent. If this option is set, the incoming TCP connection request will be accepted only

when the DSR signal is high state. Open/close TCP connection is valid only if the host mode is a TCP

client or equivalent. If the DSR behavior is set to open/close TCP connection, the high state of the

DSR pin will make the LS100M send a connection request to the specified destination host, whereas

the low state close a connection.

Inter-character timeout defines the interval that the LS100M fetches the overall serial data from its

internal buffer. If there is incoming data through the serial port, the LS100M stores data into the

internal buffer. The LS100M transfer s data stored in the buffer via TCP/IP, only if the internal buffer is

full or if the inter-character time interval reaches to the time specified as inter-character timeout.

Optimal inter-character timeout would be different according to your application but at least it must be

larger than one character interval within specified baud rate. For example, assume that the serial port

is set to 1200 bps, 8 Data bits, 1 stop bit, and no parity. In this case, the total number of bits to send a

character is 10 bits and the time required to transfer one character is

10 (bits) / 1200 (bits/s) * 1000 (ms/s) = 8.3 ms.

Therefore, you have to set inter-character timeout to be larger than 8.3 ms. The inter-character

timeout is specified in milliseconds and must be larger than 10 ms.

If users want to send the series of characters into a packet, serial device attached to the LS100M

should send characters without time delay larger than inter-character timeout between characters and

the total length of data must be smaller than or equal to the LS100M internal buffer size. The serial

communication buffer size of LS100M is 1400 bytes.

Figure 5-1 shows serial port configuration example of 9600 bps, 7 data bits, even parity, 2 stop bits,

hardware flow control, DTR shows TCP connection, No DSR behavior and inter-character time out of

10 ms:

> set serial 9600 7 e 2 h s n 10