AP-DWS1000 Drinking Water Appliance Owner’s Manual

Installation Precautions

6888931 0701

Installation and
Operating Instructions

Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.

Installation must comply with state and local
plumbing codes.

Systems certified for cyst reduction may be
used on disinfected water that may contain
filterable cysts.

System must be protected from freezing. Drain
filter when room temperature drops below
40°F (4.4°C).

Do not install on line pressure above 125 psi
(862 kPa).

Do not install on hot water line. Maximum
temperature allowed is 100°F (38°C).

The filter must be installed with the inlet and
outlet ports as labeled. Make sure not to
reverse connections.

Do not use wicking or sealer for fitting connections
into head of filter. Use Teflon

®

tape for connections.

Do not use torch or other high temperature
sources near filter or plastic cartridge.

Do not install near electric wires or water pipes
which will be in the path of drill when selecting
the position to mount bracket.

Do not install in direct sunlight.

Allow a minimum of 2” (5cm) clear space
under filter to facilitate cartridge change.

Mount filter in such a position as to prevent it
from being struck by other items.