The following tables show the estimated salt amount for each setting, as well as the estimated capacity of that salt setting for each resin amount.

Media Volume

Salt Setting

Total Salt Amount per Regeneration (lbs)

1.0

L (Low)

3.5

S (Standard)

9

H (High)

15

1.5

L (Low)

5.25

S (Standard)

13.5

H (High)

22.5

2.0

L (Low)

7

S (Standard)

18

H (High)

30

3.0

L (Low)

10.5

S (Standard)

27

H (High)

45

L = Low salt, approximately 5 lbs. per cu. ft. of media

S = Standard salt, approximately 9 lbs. per cu. ft. of media

H = High salt, approximately 15 lbs. per cu. ft. of media

To program the salt amount, press the SET button to enter the change mode. The L default will begin to fl ash. Use the UP and DOWN arrow keys to scroll through
the three settings. Press the SET button to enter the amount.

• Capacity

The controller is designed to estimate capacity of the system by multiplying the initial resin/media volume by the regenerant amount programmed in under “Amount
of regenerant used per regeneration.”

An estimated total system capacity is displayed in kilograins (kilograms CaCO

3

) that could be removed by the fully regenerated media bed. This value is derived by

standard water treatment industry norms. The system capacity is displayed merely for the installers reference when determining regeneration frequency.

NOTE: Capacity is the result of the amount of media in the tank and the salt setting. The default capacity will be changed by selecting a different salt setting.

• Hardness setting

The hardness setting is set in grains per gallon (CaCO

3

). The hardness is divided into the total capacity setting, giving a total volume of water that can be conditioned

before a regeneration is needed. To set, press SET when P8 is displayed, and use the UP or DOWN buttons to increment. Press SET again to accept the setting.

HISTORY

This level displays settings and usage information that can be used to diagnose and troubleshoot the system.

To enter the history level:

Action

Key

Duration

Display

Enter data mode

DOWN arrow and SET

5 sec.

Value for H0

Scroll through history

UP and DOWN arrows P/R

P/R

Next history value

Reset value to factory default

SET

5 secs. with value is displayed

Original factory default

Figure 23