Aqua-Pure AWS150M User Manual

Page 25

Advertising
background image

4-4

WIRING HARNESSES

The wiring harnesses are designed to fi t one way. The connectors are unique to the port they plug into. The wires are held in place by clips and the connectors
latch in place.

To remove a wiring harnesses:

1) Disconnect power to the unit.

2) Remove cover.

3) Remove controller.

4) Remove connections by squeezing the latch on the connector and pulling out.

5) Pull the harness out of the clips on the top plate.

To install a wiring harness:

IMPORTANT NOTE

Start at the back of the valve and work toward the controller. This will place any slack behind the controller. Slack or loose wires can become tangled in the
camshaft.

1) Depending on which harness is being installed, plug the connector into the motor or turbine.

2) Route the harness through the opening at the back of the top plate.

3) Place the harness into the clips on the top plate. Do not leave any slack. Put the motor wire in fi rst, then the turbine sensor cable second.

4) Feed the wire through the opening on the front of the top plate.

5) If installing the motor harness the connector to the optical sensor can be clipped in place.

6) Connect the harness to the back of the controller.

NOTE: If using both a motor and turbine cable harness, install the smaller motor cable fi rst. Install the larger turbine cable second. This will lock the motor cable
beneath in the wire management clips.

Figure 31

Figure 32

Figure 33