Aqua-Pure CWS150MECJ User Manual

Page 10

Advertising
background image

3-1

SECTION 3: CONTROL VALVE PROGRAMMING AND REGENERATION

Installer Display Settings

(Step 1)

Press SET CLOCK. Push or to change hour (AM/PM). Press NEXT then or to change

minutes. Press NEXT to lock time in.

(Step 2) Press NEXT and

simultaneously for 3 seconds.

(Step 3) Hardness: Set the amount of hardness in grains of hardness as calcium carbonate per gallon

using the

or

buttons. The default is 20 with value ranging from 1 to 150 in 1 grain increments.

NOTE

: The grains per gallon can be increased if soluble iron needs to be reduced. Press NEXT to go

to Step 3. Press REGEN to exit Installer Display Settings.

(Step 4) Day Override: Day Override sets the number of days between regenerations and sets the

maximum number of days between regenerations. If value is set as a number (allowable range from
1 to 28) a regeneration initiation will be called for on that day even if suffi cient number of gallons
were not used to call for a regeneration. Set Day Override using

or

buttons.

• number of days between regeneration (1 to 28); or “OFF”.

Press NEXT to go to Step 4. Press REGEN to return to previous step.

(Step 5) Next Regeneration Time (hour): Set the hour of day for regeneration using

or buttons.

AM/PM toggles after 12. The default time is 2:00 a.m. Press NEXT to go to Step 5. Press REGEN to
return to previous step.

(Step 6) Next Regeneration Time (minutes): Set the minutes of day for regeneration using

or

buttons. Press NEXT to exit Installer Display Settings. Press REGEN to return to previous step.

To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds.

The system will begin to regeneration immediately. The control valve may be stepped through the
various regeneration cycles by pressing the “REGEN” button.

Power Lost
If power goes out for less than eight hours, the system will automatically reset itself. If an extended

power outage occurs, the time of day will fl ash on and off which indicated the time of day should be
reset. The system will remember the rest.

Error Message
If the word “error” and a number are alternately fl ashing on the display contact your Dealer/

Installer or our Customer Service Department at 1-800-222-7880 for help. This indicates that the
valve was not able to function properly.

RETURN TO

NORMAL MODE

Step 3

Step 4

Step 5

Step 6