Aqua-Pure CWS150MECJ User Manual

Page 20

Advertising
background image

7-1

ITEM

CWS100ME

CWS100MECJ

CWS150ME

CWS150MECJ

CWS200ME

CWS200MECJ

CWS300ME

CWS300MECJ

Nominal Media Volume, Ft

3

1.0

1.5

2.0

3.0

Salt Dosage, Lbs.

Salt Effi cient Setting

4

6

8

12

Factory Setting

6

9

12

18

Maximum Setting

16

16

24

36

Softening Capacity, grains

At Salt Effi cient Setting

16,300

24,200

34,100

51,100

At Factory Salt Setting

21,600

32,000

45,000

67,600

At Maximum Salt Setting

29,000

43,000

56,800

85,200

Salt Effi ciency, grains per lb. of salt

At Salt Effi cient Setting

4,078

4,026

4,260

4,260

Flow Rate At 15 psi Pressure Loss

7.9

11.1

9.6

15.7

Pressure Loss, psi At Service Flow

4

5

5

4

Regeneration Flow Rates, gpm

Backwash

1.7

2.7

2.7

5.3

Brine Draw @ 50 psi

0.18

0.26

0.26

0.45

Slow Rinse @ 50 psi

0.27

0.34

0.36

0.71

Rapid Rinse

1.7

2.7

2.7

5.3

Brine Refi ll

0.5

0.5

0.5

0.5

Approximate Water Used (at Factory Setting)

44

77

78

148

Regeneration Duration, minutes a (at Factory Setting)

1st Backwash

6

6

6

6

Brine Draw/Rinse

45

45

45

45

2nd Backwash

3

3

3

3

Rapid Rinse

3

3

3

3

Brine Refi ll

3’ 51”

3’ 51”

7’ 52”

7’ 52”

Approximate Total Time

61

63

65

69

Inlet/Outlet Size

1” NPT

1” NPT

1” NPT

1” NPT

Media tank Dia. x Ht., in.

8 x 44

10 x 44

10 x 54

14 x 65

Overall D & H w/Valve, in.

Width (Including Brine Tank)

33

35

35

42

Depth

15

15

15

18

Height (Including Valve)

53

53

63

74

Brine Tank, W x D x H, in.

15 x 15 x 34

15 x 15 x 34

15 x 15 x 34

18 x 33

Salt settings below 6# require removal of the salt grid
Salt settings above 24# require optional 18 x 33 brine tank
*Salt settings above 35# require optional 24 x 50 brine tank

Brine Tank Capacity

Without Salt Grid Leg Extensions

180

180

180

300

With Salt Grid Leg Extensions

(required on salt settings above 18 #)

NA

135

135

300

Approximate Shipping Wt.

97

125

154

244

These softeners conform to NSF/ANSI Standard 44 for specifi c performance claims. When set at the Salt Effi cient setting, these softeners meet or exceed Std. 44 requirement for salt effi ciency. Effi ciency claim is only
valid at the Salt Effi cient Setting.
NOTES: For satisfactory performance, indicated fl ow rates and duration should not be exceeded. Flow rates specifi ed are adequate for normal residential applications. Do not use Service Flow Rate if treated water is to sup-

ply a geothermal heat pump, swimming pool, etc. (contact your Dealer/Installer or our Customer Service Department at 1-800-222-7880 before selecting equipment). Service fl ow rates have been tested against
NSF Standard 44.