LEDset SPECIFICATIONS

2.3.5. Color coding

2.3.7. Fault conditions/troubleshooting

2.3.6. Cable length

2.3.7.1. Incorrect wiring

2.3.7.2. Missing control wire (Vset)

The color coding for the connector of the LEDset interface is

defi ned as follows:

LED+ and LED- are the power outputs of the control gear.

The position and order of the terminals can vary between the

different LEDset ECG types.

The maximum length of LEDset cables should not exceed

2 m. Further limitations to cable length generally derive from

EMI emission or immunity issues or directly from product

specifi cation details. For detailed information, please refer to

the datasheet or instruction sheet of the respective LEDset

control gear.

The LEDset interface has been designed to inherently pro-

tect itself and the LED module against incorrect wiring on the

secondary side of the control gear. Incorrect connections

between LED+ and Vset or GNDset can irreversibly damage

the ECG.

Other possible incorrect wirings on the secondary side do

not affect the operation of the ECG once they are removed

(irrespective of problems regarding the connected external

LEDset ECGs).

LEDset is an interface intended for the current setting and

thermal management of an LED module. If the Vset terminal

is not connected to the control unit, the thermal protection of

the LED module and its correct current setting will not work.

This fault condition may result in an undetected overheating

of the LED module. In order to protect the LED module in

this condition, the absence of a control signal (Vset open or

Vset ≥ 11 V) is detected and the ECG is shut down or set to
its minimum current (see fi gure 3).

Table 3: Color coding.

LED+

Red

LED-

Black

LEDset GNDset

Gray

LEDset Vset

Violet

LEDset +12Vset

Blue