Example:

Requirements:

Tset

H

= 75 °C

Tset

L

= 60 °C

ΔT

Hyst

= 5 °C

Iout = Inom

max

Iout

warning

= from 100 % to 60 % Inom

max

in a linear way

Iout

fault

= 0 mA

LEDset APPLICATIONS

Figure 37: Thermal derating – NTC + OPAMP solution: continuous derating and
switch-off characteristic (example).

By selecting the following components,
the result shown in fi gure 37 can be achieved:

R

1

= 100 kΩ 0603 1 % (general purpose)

R

2

= 270 kΩ 0603 1 % (general purpose)

R

3

= 0R 0603 1 % (general purpose)

R

4

= 681 kΩ 0603 1 % (general purpose)

R

5

= 36.8 kΩ 0603 1 % (general purpose)

R

6

= Not mounted (general purpose)

Rset

1

= 18 kΩ 0603 1 % (general purpose)

Rset

2

= 22 kΩ 0603 1 % (general purpose)

Rset

3

= Not mounted

R

NTC

= NTCS0805E3683GXT (680 kΩ 2 % 0805) (glass-protected – Vishay)

D

1

= 1N4148 (general purpose)

U

1

= LM2904M – SO8 (general purpose)

Q

1

= BC847 – SOT23 (general purpose)

C

1

, C

2

= 100 nF X7R 0603 (general purpose)

(by-pass capacitor to be placed as close as possible to the power pins of U1)
C3 = 1 nF COG 0603 (general purpose)
(by-pass capacitor to be placed across D1)

Notes:
• Rset = Rset

1

+ Rset

2

sets the Inom.

• The dividing rate between Rset

1

and Rset

2

allows adjusting the Iout

warning

output slope

level.

• The distribution of the resistance values of R

1

, R

2

and R

5

allows setting and

adjusting the Tset

H

and Tset

L

temperature trip thresholds.

• Moving the values of R

4

allows adjusting the respective ΔT

Hyst

. Increasing the

resistance value decreases the ΔT

Hyst

and vice versa.

2

1

Figure 38: NTC + OPAMP solution: continuous derating and switch-off –
real circuit (1) appearance with connector block (2).