OT EASY 60

IV 2009

Operation

Setting the fade and cycle time

Set the fade time for the sequencer mode and the cycle time for the daylight simula-
tion.

To increase the time: „Start/Time+“ button

To decrease the time: „Stop/Time

−“ button

Proceed as follows:

Step

Task

1

Press the button for at least 3 seconds. The time is shown on the display;
see below.

2

Single steps: Short press
Fast forward: Long press

Operating mode

Display

Interval

Sequencer mode (fade time)

Effect Lighting

Wellness

Long Time

Tenths of a second

Seconds

Minutes

Daylight simulation (cycle time)

Hours

Example of a sequence

Fade time

Hold time*

Brightness

Time

Red:

Green:

Blue:

Scene 1

Scene 2

Scene 3

*The hold time is automatically set to 25% of the set fade time.

Scene 1:

Ch1 (red) = max.; Ch2,Ch3,Ch4 = min.

Scene 2:

Ch2 (green) = max; Ch1,Ch3,Ch4 = min.

Scene 3:

Ch3 (blue) = max.; Ch1,Ch2,Ch4 = min.

Scene 4:

Ch1...Ch4 = off (is skipped)