OSRAM OPTOTRONIC OT EASY 60 II User Manual

Page 8

Advertising
background image

8

IV 2009

OT EASY 60

Installation

Connecting the inputs

Proceed as follows:

Step

Task

1

Connect the 4p4c modular connector of the EASY signal line.

2

Strip the power cable, remove the insulation from the phase and neu-
tral wires and connect to the screw terminals.

3

Connect the line of the external pushbutton to the screw terminals, if
applicable.

4

Mount the cable strain relief: Use a rubber adapter and cable clamp

that are suitable for the power cable diameter; see figure.

5

Insulate the PE conductor, if necessary.

Ø (G) mm

Cable strain relief

6 - 7.5

E
F

G

H

7.5 - 8.5

8.5 - 9

E

Modular cable

F

Rubber adapter for modular cable

G Power cable

H Cable clamps