OT EASY 60
Installation
Connecting the inputs
Proceed as follows:
Step
Task
1
Connect the 4p4c modular connector of the EASY signal line.
2
Strip the power cable, remove the insulation from the phase and neu-
tral wires and connect to the screw terminals.
3
Connect the line of the external pushbutton to the screw terminals, if
applicable.
4
Mount the cable strain relief: Use a rubber adapter and cable clamp
that are suitable for the power cable diameter; see figure.
5
Insulate the PE conductor, if necessary.
Ø (G) mm
Cable strain relief
6 - 7.5
E
F
G
H
7.5 - 8.5
8.5 - 9
E
Modular cable
F
Rubber adapter for modular cable
G Power cable
H Cable clamps