WIRING AND CONFIGURATION OF THE ECG

4.2.2. Parameter setting via 3DIM Tool
The StepDIM operation is defi ned by three parameters:
power-on level, dim level and dim fade time. In addition,
StepDIM can be operated according to two different signal
logics.

The SD control states HIGH and LOW refer to the different
output power levels of the ECG. By default, LOW means
that the ECG provides the power-on level and HIGH
means that the ECG provides the dim level (see fi gure 19).

Via the 3DIM Tool, it is possible to select the “StepDIM
inverse/DALI” mode, which reverses the logical relation
between the SD control state and the ECG output power
level (see fi gure 20).

The power-on level and dim level are set as a percentage
of the nominal output current or power (depending on the
output type of the ECG).

Note: The power-on level and dim level depend on the
nearest admissible DALI

®

value. Setting an intermediate

value results in a rounding to the nearest admissible value
(see table below).

Table 4: StepDIM parameters

Parameter

Description

Power-on level

Output power level of the ECG
(in % of the nominal value of the ECG/
lamp combination) after switch-on via
the mains.

Dim level*

Output power level of the ECG
(in % of the nominal value of the ECG/
lamp combination) after the SD state
has changed.

Dim fade time**

Transition time between power-on level
and dim level.

StepDIM signal logic

StepDIM polarity

The polarity of the input signal used
for dim activation can be changed →
“StepDIM inverse/DALI” mode.

Table 5: DALI

®

logarithmic dimming curve*

8-bit arc power level

Arc power (%)

3DIM level (%)

254

100.000

100

253

97.307

97

252

94.686

95

251

92.135

92

250

89.654

90

249

87.239

87

248

84.889

85

247

82.603

83

246

80.378

80

245

78.213

78

*

Please note that the dim level is also referred to as “Dim level 1”

in the 3DIM Tool.

** Can only be set for OPTOTRONIC

®

3DIM ECGs.

* See IEC 62386-102, table 9.1.