PrevaLED

®

Core Z3 LED modules

|

Thermal considerations

Please note:
A thermal design must always be confi rmed by performing
a thermal measurement in steady-state condition.The whole
area of the PCB must be in contact with solid material of the
heat sink. In the following, you fi nd two examples of how to
cool a PrevaLED

®

Core Z3 LED module.

Example 1:

LED module: PL-CORE 1100-827
Heat sink: Fischer SK572 height: 37.5 mm
TIM: Kerafoil 86/82
T

ambient

: 25 °C

Temperature at the t

c

point: 61 °C

Example 2:

LED module: PL-CORE 5000-830
Heat sink: Sunon LA003-012A82DY
(active cooling solution with 12-V fan)
TIM: Kerafoil 86/82
T

ambient

: 25 °C

Temperature at the t

c

point: 57 °C

Please note that the shown solutions are just examples. A
thermal system always depends on many factors, such as
airfl ow, ambient temperature etc. Please check your entire
cooling system by performing a thermal measurement in
steady-state condition. The list below is a selection of sup-
pliers of different cooling solutions.

4.4 T

c

point location and temperature measurement

The t

c

point is the location to check if the chosen cooling

solution (heat sink and TIM) is suffi cient to ensure the LED
module performance. The t

c

point is located on the back of

the LED module under the center of the diffuser (see image
below).

To ensure a lifetime of 50000 hours (L

70

B

50

), the reference

temperature (t

r

) at the t

c

point must not exceed 65 °C. The

maximum temperature reached at the t

c

point must not

exceed 85 °C. A correct temperature measurement can,
for example, be performed with a thermocouple.

4.5 Thermocouple

Use a thermocouple that can be glued onto the LED module.
Make sure that the thermocouple is fi xed with direct contact
to the t

c

point. Examples of suitable thermo couples:

Cooling systems

Nuventix

www.nuventix.com

Sunon

www.sunoneurope.com

Cooler Master

www.coolermaster.com

AVC

www.avc-europa.de

SEPA

www.sepa-europe.com

Fischer Elektronik

www.fischerelektronik.de

Meccal www.meccal.com

Wakefield www.wakefield.com

R-Theta www.r-theta.com

Cool Innovations

www.coolinnovations.com

Different thermocouples

Illustration

Description

Temperature range [°C]

PVC-insulated

thermo couple

-10 … +105

PFA-insulated

thermo couple

-75 … +260

Sprung

thermo couple

-75 … +260

K-type thermocouple with miniature connector

t

c

point

2D code

Location of the t

c

point

Advertising