Mechanical considerations

6 Mechanical considerations

The following schematic drawing provides further details on
the dimensions of PrevaLED

®

Core Z3 LED modules. For 3D

fi les of the LED modules, please go to:

www.osram.com

.

6.1 Outline drawing

For operation in damp, wet or dusty environments, the user
has to make sure that an adequate ingress protection is
chosen. The LED module has to be protected by a suitable
IP classifi cation of the luminaire housing. Please con sider
the luminaire standard IEC 60598-1 as well as the different
requirements.

6.4 Mounting

To fi x a PrevaLED

®

Core Z3 LED module to a heat sink, you

can use M3 cylinder head screws according to DIN 7984. If
you cannot use DIN screws, please use the following speci-
fi cation: Height of head not more than 2.6 mm, diameter of
head below 5.5 mm. The allowed torque is 0.4 to 0.6 Nm.

6.3 Mechanical protection of the PrevaLED

®

Core Z3

LED module

The housing of a PrevaLED

®

Core Z3 LED module should

not be exposed to strong mechanical stress. Please apply
force only to the dedicated mounting positions. Strong me-
chanical stress can lead to irreversible damage of
the LED module.

Note: Please do not touch or mechanically stress
the yellow chip-on-board surface. This could damage
the module.

6.2 3D drawing