Data sheet, Absolute maximum ratings, Electrical specifications – GE Industrial Solutions EBVW020A0B Barracuda Series User Manual

Page 2

Advertising
background image

GE

Data Sheet

EBVW020A0B Barracuda Series; DC-DC Converter Power Modules

36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output

July 22, 2013

©2012 General Electric Company. All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations

sections of the Data Sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage*

Continuous

V

IN

-0.3 75

V

dc

Operating transient ≤ 100mS

100

V

dc

Operating Input transient slew rate, 50V

IN

to 75V

IN

(Output may exceed regulation limits, no protective
shutdowns shall activate, C

O

=220μF to C

O, max

)

- - 10

V/µs

Non- operating continuous

V

IN

80 100

V

dc

Operating Ambient Temperature

All

T

A

-40 85

°C

(See Thermal Considerations section)

Storage Temperature

All

T

stg

-55 125

°C

I/O Isolation Voltage (100% factory Hi-Pot tested)

All

2250 V

dc

* Input over voltage protection will shutdown the output voltage, when the input voltage exceeds threshold level.

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

V

IN

36

48

75

V

dc

Maximum Input Current

I

IN,max

- - 7 A

dc

(V

IN

=0V to 75V, I

O

=I

O, max

)

Input No Load Current

All I

IN,No load

50 mA

(V

IN

= V

IN, nom

, I

O

= 0, module enabled)

Input Stand-by Current

All I

IN,stand-by

25 mA

(V

IN

= V

IN, nom

, module disabled)

External Input Capacitance

All

100

-

-

μF

Inrush Transient

All

I

2

t -

-

1

A

2

s

Input Terminal Ripple Current
(Measured at module input pin with maximum specified input
capacitance and ൏ 500uH inductance between voltage source

and input capacitance C

IN

=220uF, 5Hz to 20MHz, V

IN

= 48V, I

O

=

I

Omax

)

All

-

900

-

mA

rms

Input Reflected Ripple Current, peak-to-peak

(5Hz to 20MHz, 12μH source impedance; V

IN

= 48V, I

O

= I

Omax

; see

Figure 12)

All

-

24

-

mA

p-p

Input Ripple Rejection (120Hz)

All

-

50

-

dB

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part
of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum
safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating
of 15 A (see Safety Considerations section). Based on the information provided in this Data Sheet on inrush energy and maximum
dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s Data Sheet for further
information.