Absolute maximum ratings, Electrical specifications, Input; 14.0v – GE Industrial Solutions EBVW017A0S14R0 Series User Manual

Page 2: Output; 17a output current

Advertising
background image

Data Sheet
April 11, 2013

EBVW017A0S14R0 Series Power Modules; DC-DC Converters

36-75V

dc

Input; 14.0V

dc

Output; 17A Output Current

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those
given in the operations sections of the Data Sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage*

Continuous

V

IN

-0.3 75 V

dc

Operating transient ≤

100mS

100

V

dc

Operating Input transient slew rate, 50V

IN

to 75V

IN

(Output may exceed regulation limits, no protective
shutdowns shall activate, C

O

=220μF to C

O, max

)

- - 10

V/µs

Non- operating continuous

V

IN

80 100 V

dc

Operating Ambient Temperature

All

T

A

-40 85 °C

(See

Thermal

Considerations

section)

Storage Temperature

All

T

stg

-55 125 °C

I/O Isolation Voltage (100% factory Hi-Pot tested)

All

2250 V

dc

* Input over voltage protection will shutdown the output voltage, when the input voltage exceeds threshold level.

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

V

IN

36 48

75 V

dc

Maximum Input Current

I

IN,max

- - 7

A

dc

(V

IN

=0V to 75V, I

O

=I

O, max

)

Input No Load Current

All I

IN,No load

50 mA

(V

IN

= V

IN, nom

, I

O

= 0, module enabled)

Input Stand-by Current

All I

IN,stand-by

25 mA

(V

IN

= V

IN, nom

, module disabled)

External Input Capacitance

All

100

-

-

μF

Inrush Transient

All

I

2

t - - 1

A

2

s

Input Terminal Ripple Current
(Measured at module input pin with maximum
specified input capacitance and

൏ 500uH inductance

between voltage source and input capacitance
C

IN

=220uF, 5Hz to 20MHz, V

IN

= 48V, I

O

= I

Omax

)

All

-

900

- mA

rms

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; V

IN

= 48V,

I

O

= I

Omax

; see Figure 12)

All

-

24

-

mA

p-p

Input Ripple Rejection (120Hz)

All

-

50

-

dB

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a
fast-acting fuse with a maximum rating of 15 A (see Safety Considerations section). Based on the information provided in
this Data Sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used.
Refer to the fuse manufacturer’s Data Sheet for further information.