Feature Descriptions

Overcurrent Protection

To provide protection in a fault output overload condition,
the module is equipped with internal current-limiting
circuitry and can endure current limiting continuously. If the
overcurrent condition causes the output voltage to fall
greater than 4.0V from V

o,set

, the module will shut down and

remain latched off. The overcurrent latch is reset by either
cycling the input power or by toggling the on/off pin for one
second. If the output overload condition still exists when the
module restarts, it will shut down again. This operation will
continue indefinitely until the overcurrent condition is
corrected.
A factory configured auto-restart option (with overcurrent
and overvoltage auto-restart managed as a group) is also
available. An auto-restart feature continually attempts to
restore the operation until fault condition is cleared.

Remote On/Off

The module contains a standard on/off control circuit
reference to the V

IN

(-) terminal. Two factory configured

remote on/off logic options are available. Positive logic
remote on/off turns the module on during a logic-high
voltage on the ON/OFF pin, and off during a logic low.
Negative logic remote on/off turns the module off during a
logic high, and on during a logic low. Negative logic, device
code suffix "1," is the factory-preferred configuration. The
On/Off circuit is powered from an internal bias supply,
derived from the input voltage terminals. To turn the power
module on and off, the user must supply a switch to control
the voltage between the On/Off terminal and the V

IN

(-)

terminal (V

on/off

). The switch can be an open collector or

equivalent (see Figure 15). A logic low is V

on/off

= -0.3V to

0.8V. The typical I

on/off

during a logic low (Vin=48V, On/Off

Terminal=0.3V) is 147µA. The switch should maintain a
logic-low voltage while sinking 310µA. During a logic high,
the maximum V

on/off

generated by the power module is

8.2V. The maximum allowable leakage current of the
switch at V

on/off

= 2.0V is 10µA. If using an external voltage

source, the maximum voltage V

on/off

on the pin is 14.5V

with respect to the V

IN

(-) terminal.

If not using the remote on/off feature, perform one of the
following to turn the unit on:
For negative logic, short ON/OFF pin to V

IN

(-).

For positive logic: leave ON/OFF pin open.

Figure 15. Remote On/Off Implementation.

Output Overvoltage Protection

The module contains circuitry to detect and respond to
output overvoltage conditions. If the overvoltage condition

causes the output voltage to rise above the limit in the
Specifications Table, the module will shut down and remain
latched off. The overvoltage latch is reset by either cycling
the input power, or by toggling the on/off pin for one
second. If the output overvoltage condition still exists when
the module restarts, it will shut down again. This operation
will continue indefinitely until the overvoltage condition is
corrected.
A factory configured auto-restart option (with overcurrent
and overvoltage auto-restart managed as a group) is also
available. An auto-restart feature continually attempts to
restore the operation until fault condition is cleared.

Overtemperature Protection

These modules feature an overtemperature protection
circuit to safeguard against thermal damage. The circuit
shuts down the module when the maximum device
reference temperature is exceeded. The module will
automatically restart once the reference temperature cools
by ~25°C.

Input Under/Over voltage Lockout

At input voltages above or below the input under/over
voltage lockout limits, module operation is disabled. The
module will begin to operate when the input voltage level
changes to within the under and overvoltage lockout limits.

Thermal Considerations

The power modules operate in a variety of thermal
environments and sufficient cooling should be provided to
help ensure reliable operation.
Thermal considerations include ambient temperature,
airflow, module power dissipation, and the need for
increased reliability. A reduction in the operating
temperature of the module will result in an increase in
reliability. The thermal data presented here is based on
physical measurements taken in a wind tunnel.
Heat-dissipating components are mounted on the top side
of the module. Heat is removed by conduction, convection
and radiation to the surrounding environment. Proper
cooling can be verified by measuring the thermal reference

temperature (TH

x

). Peak temperature (TH

x

) occurs at the

position indicated in Figure 18 and 19. For reliable
operation this temperature should not exceed the listed
temperature threshold.

Figure 18. Location of the thermal reference
temperature TH

1

. Do not exceed 113 °C.