Car1212dc series dc-dc converter, Data sheet, Input: -36v – GE Industrial Solutions CAR1212DC series User Manual

Page 12: Output: 12v, Or 5 v, Status register bit allocation, Command descriptions

Advertising
background image

GE

Data Sheet

CAR1212DC series DC-DC converter

Input: -36V

D C

to -75V

DC

; Output: 12V

DC

@ 1200W; 3.3V

DC

or 5 V

DC

@ 1A

October 21, 2013

©2013 General Electric Company. All rights reserved.

Page 12

Status Register Bit Allocation:

Register

Hex

Code

Data

Byte

Function

Status_Byte

[ 0 – normal

1 – fault]

78

7

Busy

6

DC_ OFF

5

Output OV Fault

4

Output OC Fault

3

Input UV Fault

2

Temp Fault/warning

1

CML (communication fault)

0

None of Below

Status_word

(includes

Status_byte)

[ 0 – normal

1 – fault]

79

7

OV Fault/Warning detected

6

OC Fault/Warning detected

5

Input Fault/Warning

4

Mfr_specific register change

3

nPower_Good

2

Fan Fault or Warning

1

Other fault

0

Unknown

Status_Vout

[ 0 – normal

1 – fault]

7A

7

Vout OV Fault

6

Vout OV Warning

5

Vout UV Warning

4

Vout UV Fault

3

N/A

2

N/A

1

N/A

0

N/A

Status_Iout

[ 0 – normal

1 – fault]

7B

7

IOUT OC Fault

6

N/A

5

IOUT OC Warning

4

N/A

3

N/A

2

N/A

1

N/A

0

N/A

Status_input

[ 0 – normal

1 – fault]

7C

7

Vin OV Fault

6

Vin OV Warning

5

Vin UV Warning

4

Vin UV Fault

3

N/A

2

N/A

1

N/A

0

N/A

Status_temperature

[ 0 – normal

1 – fault]

7D

7

OT Fault

6

OT Warning

5

N/A

4

N/A

3

N/A

2

N/A

1

N/A

0

N /A

Status_cml

[ 0 – normal

1 – fault]

7E

7

Invalid/Unsupported Command

6

Invalid/Unsupported Data

5

Packet Error Check Failed

4

Memory Fault Detected

3

Processor Fault Detected

2

Reserved

1

Other Communications Fault

0

Other Memory or Logic Fault

Register

Hex

Code

Data

Byte

Function

Status_mfr_specific

[ 1 – normal

0 –fault]

80

7

3.3V_fault

6

OVSD

5

Interrupt

4

Fault detected

3

PS_remote_OFF

2

DC_fault

1

INPUT_fault

0

N/A

Status_fan_1_2

[ 0 – normal

1 – fault]

81

7

Fan 1 Fault

6

Fan 2 Fault

5

N/A

4

N/A

3

Fan 1 Speed Overridden

2

Fan 2 Speed Overridden

1

N/A

0

N/A


Command Descriptions

Operation (01) :

By default the Power supply is turned ON at power

up as long as Power ON/OFF signal pin is active HI. The Operation

command is used to turn the Power Supply ON or OFF via the

PMBus. The data byte below follows the OPERATION command.

FUNCTION

DATA BYTE

Unit ON

80

Unit OFF

00


To RESET the power supply cycle the power supply OFF, wait at

least 2 seconds, and then turn back ON. All alarms and shutdowns

are cleared during a restart.

Clear_faults (03):

This command clears all STATUS and FAULT

registers and resets the SMBAlert# line.
If a fault still persists after the issuance of the clear_faults

command the specific registers indicating the fault are reset and

the SMBAlert# line is activated again.

WRITE_PROTECT register (10):

Used to control writing to the PMBus

device. The intent of this command is to provide protection against

accidental changes. All supported command parameters may have

their parameters read, regardless of the write_protect settings. The

contents of this register can be stored to non-volatile memory using

the Store_default_code command. The default setting of this

register is disable_all_writes except write_protect 0x80h. This

default cannot be changed.

FUNCTION

DATA BYTE

Enable all writes

00

Disable all writes except write_protect

80

Disable all writes except write_protect and

OPERATION


Vout_Command (21) :

This command is used to change the output

voltage of the power supply. Changing the output voltage should be

performed simultaneously to all power supplies operating in parallel

using the Global Address (Broadcast) feature. If only a single power

supply is instructed to change its output, it may attempt to source

all the required power which can cause either a power limit or

shutdown condition.
Software programming of output voltage permanently overrides

the set point voltage configured by the Vprog signal pin. The

program no longer looks at the ‘Vprog pin’ and will not respond to

any hardware voltage settings. If power is removed from the

µController it will reset itself into its default configuration looking at

the Vprog signal for output voltage control. In many applications,

Advertising