Absolute maximum ratings, Electrical specifications, Car1212dc series dc-dc converter – GE Industrial Solutions CAR1212DC series User Manual

Page 2: Data sheet, Input: -36v, Output: 12v, Or 5 v

Advertising
background image

GE

Data Sheet

CAR1212DC series DC-DC converter

Input: -36V

D C

to -75V

DC

; Output: 12V

DC

@ 1200W; 3.3V

DC

or 5 V

DC

@ 1A

October 21, 2013

©2013 General Electric Company. All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional

operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet.

Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Symbol

Min

Max

Unit

Input Voltage: Continuous

V

IN

0

75

V

DC

Operating Ambient Temperature

T

A

-10

70

1

°C

Storage Temperature

Tstg

-40

85

°C

I/O Isolation voltage (100% factory Hi-Pot tested)

1500

V

DC

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions.

INPUT

Parameter

Symbol

Min

Typ

Max

Unit

Operational Range

V

IN

-36

-48/60

-75

V

DC

12V

DC

output turned OFF

-35

12V

DC

output turned ON

-36

Idling Power 12V

DC

output OFF

W

35

W

12V

DC

output ON

45

Maximum Input Current V

IN

= -36V

DC

I

IN

38

A

DC

(V

OUT

= V

O, set

, I

OUT

=I

O, max

)

Cold Start Inrush Current

I

IN

40

A

PEAK

(Excluding x-caps, 25°C, <10ms, per ETSI 300-132)
Efficiency

η

90

%

(T

amb

=25°C, V

IN

= -48V

DC

, V

OUT

= 12V

DC

, 60-80% load)

Holdup time (V

IN

= -48V

DC

, V

OUT

≥ 10.8Vdc, T

AMB

25°C,

I

OUT

=I

O, max

)

T

2.5

ms

Isolation Input/Output

1500

V

DC

Input/Frame

1500

V

DC

Output/Frame

100

V

DC

12V

DC

MAIN OUTPUT

Parameter

Symbol

Min

Typ

Max

Unit

Output power

P

OUT

0

1200

W

Set point @ 50% load

V

OUT

11.9

12.00

12.1

V

DC

Overall regulation (load, temperature)

-2

+2

%

Remote sense sum of hot & return

0.25

V

DC

Ripple and noise

2

120

mV

p-p

1

Derated above 50°C at 2.5%/°C

2

Measured across a 10µf tantalum and a 0.1µf ceramic capacitors in parallel. 20MHz bandwidth

Advertising