Feature specifications – GE Industrial Solutions ESTW010A0A Series User Manual

Page 4

Advertising
background image

Data Sheet

November 29, 2011

ESTW010A0A Series Eighth-Brick Power Modules

36

–75Vdc Input; 5.0Vdc Output; 10A Output Current

LINEAGE

POWER

4

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current

All

I

on/off

0.15

mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

0.6

V

dc

Logic High Voltage

– (Typ = Open Collector)

All

V

on/off

2.4

15

V

dc

Logic High maximum allowable leakage current

All

I

on/off

25

μA

Turn-On Delay

1

and Rise Times

(I

O

=I

O, max ,

V

IN

=V

IN, nom,

T

A

= 25

o

C)

Case 1: Input power is applied for at least 1 second
and then the On/Off input is set from OFF to ON (T

delay

= from instant at which On/Off signal is ON until V

O

=

10% of V

O, set

).

All

T

delay

20

msec

Case 2: On/Off input is set to Logic Low (Module
ON) and then input power is applied (T

delay

from

instant at which V

IN

= V

IN, min

until V

o

=10% of V

O,set

)

All

T

delay

150

msec

Output voltage Rise time (time for V

o

to rise from 10%

of V

o,set

to 90% of V

o, set

)

All

T

rise

15

msec

Output voltage overshoot

– Startup

All

3

% V

O, set

I

O

= I

O, max

; V

IN

=V

IN, min

to V

IN, max

, T

A

= 25

o

C

Prebias Output Load Performance:

All

Monotonic

Output Start up characteristic

Back Bias current drawn from output (Module Enabled)

All

-150

mA

dc

Remote Sense Range

All

V

SENSE

10

% V

O, set

Output Voltage Adjustment range

All

80

110

% V

O, set

Output Overvoltage Protection

(Co,min=220 μF)

2

All

V

O, limit

6.0

7.0

V

dc

Overtemperature Protection

– Hiccup Auto Restart

All

T

ref

135

O

C

Input Undervoltage Lockout

All

V

UVLO

Turn-on Threshold

32

34.5

V

dc

Turn-off Threshold

27.5

30

V

dc

Hysteresis

1

2

V

dc

1.

The module has an adaptable extended Turn-On Delay interval, T

delay

, of 20mS. The extended T

delay

will occur when the module restarts

following either: 1) the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout (which causes module
shutdown), and then back to normal; or 2) toggling the on/off signal from on to off and back to on without removing the input voltage. The
normal Turn-On Delay interval, T

delay

, will occur whenever a module restarts with input voltage removed from the module for the preceding 1

second.

2.

The module requires a minimum of 220

μF external output capacitor to prevent shutdown during no load to full load transients and to avoid

exceeding the OVP maximum limits during startup into open loop fault conditions.

Advertising