Emc considerations – GE Industrial Solutions EVW020A0A Series (Eighth-Brick) User Manual

Page 13

Advertising
background image

Data Sheet

September 7, 2012

EVW020A0A Series Eighth-Brick Power Modules

36–75Vdc Input; 5.0Vdc Output; 20A Output Current

LINEAGE

POWER

13

EMC Considerations

The circuit and plots in Figure 25 shows a suggested configuration to meet the conducted emission limits of EN55022
Class B.

0

10

20

30

40

50

60

70

80

Level [dBµV]

150k

300k

500k

1M

2M

3M

4M 5M

7M

10M

30M

Frequency [Hz]

+

+ +

MES CE1204081008_fin AV
MES CE1204081008_pre AV

0

10

20

30

40

50

60

70

80

Level [dBµV]

150k

300k

500k

1M

2M

3M

4M 5M

7M

10M

30M

Frequency [Hz]

x

x x

MES CE1204081008_fin QP
MES CE1204081008_pre PK

Figure 25. EMC Considerations

For further information on designing for EMC compliance, please refer to the FLT007A0 data sheet (DS05-028).

Advertising