EVW020A0A Series Eighth-Brick Power Modules
36–75Vdc Input; 5.0Vdc Output; 20A Output Current
LINEAGE
POWER
13
EMC Considerations
The circuit and plots in Figure 25 shows a suggested configuration to meet the conducted emission limits of EN55022
Class B.
0
10
20
30
40
50
60
70
80
Level [dBµV]
150k
300k
500k
1M
2M
3M
4M 5M
7M
10M
30M
Frequency [Hz]
+
+ +
MES CE1204081008_fin AV
MES CE1204081008_pre AV
0
10
20
30
40
50
60
70
80
Level [dBµV]
150k
300k
500k
1M
2M
3M
4M 5M
7M
10M
30M
Frequency [Hz]
x
x x
MES CE1204081008_fin QP
MES CE1204081008_pre PK
Figure 25. EMC Considerations
For further information on designing for EMC compliance, please refer to the FLT007A0 data sheet (DS05-028).