Data Sheet

EHHD015A0A Hammerhead™ Series; DC-DC Converter Power Modules

18-75Vdc Input; 5Vdc, 15.0A, 75W Output

April 4, 2013

©2012 General Electric Company. All rights reserved.

Page 7

Feature Descriptions

Remote On/Off

Two remote on/off options are available. Positive logic turns
the module on during a logic high voltage on the ON/OFF
pin, and off during a logic low. Negative logic remote On/Off,
device code suffix “1”, turns the module off during a logic
high and on during a logic low.

ON/OFF

Vin+

Vin-

I

on/off

V

on/off

Vout+

TRIM

Vout-

Figure 10. Remote On/Off Implementation.

To turn the power module on and off, the user must supply a
switch (open collector or equivalent) to control the voltage
(V

on/off

) between the ON/OFF terminal and the V

IN

(-) terminal

(see Figure 10). Logic low is 0V ≤ V

on/off

≤ 1.2V. The maximum

I

on/off

during a logic low is 1mA; the switch should maintain a

logic low level whilst sinking this current.
During a logic high, the typical maximum V

on/off

generated

by the module is 5V, and the maximum allowable leakage
current at V

on/off

= 5V is 1μA.

If not using the remote on/off feature:
For positive logic, leave the ON/OFF pin open.
For negative logic, short the ON/OFF pin to V

IN

(-).

Remote Sense

Remote sense minimizes the effects of distribution losses by
regulating the voltage at the remote-sense connections (See
Figure 11). The voltage between the remote-sense pins and
the output terminals must not exceed the output voltage
sense range given in the Feature Specifications table:
[V

O

(+) – V

O

(–)] – [SENSE(+) – SENSE(–)]  0.5 V

Although the output voltage can be increased by both the
remote sense and by the trim, the maximum increase for
the output voltage is not the sum of both. The maximum
increase is the larger of either the remote sense or the trim.

The amount of power delivered by the module is defined as

the voltage at the output terminals multiplied by the output
current. When using remote sense and trim, the output

voltage of the module can be increased, which at the same
output current would increase the power output of the
module. Care should be taken to ensure that the maximum

output power of the module remains at or below the
maximum rated power (Maximum rated power = Vo,set x
Io,max).

Figure 11. Circuit Configuration for remote sense .

Input Undervoltage Lockout

At input voltages below the input undervoltage lockout limit,
the module operation is disabled. The module will only
begin to operate once the input voltage is raised above the

undervoltage lockout turn-on threshold, V

UV/ON

.

Once operating, the module will continue to operate until
the input voltage is taken below the undervoltage turn-off

threshold, V

UV/OFF

.

Overtemperature Protection

To provide protection under certain fault conditions, the unit
is equipped with a thermal shutdown circuit. The unit will
shutdown if the thermal reference point, Tref, exceeds 135

O

C (Figure 13, typical) or 120

O

C (Figure 14, typical), but the

thermal shutdown is not intended as a guarantee that the
unit will survive temperatures beyond its rating. The module
will automatically restart upon cool-down to a safe
temperature.

Output Overvoltage Protection

The output over voltage protection scheme of the modules
has an independent over voltage loop to prevent single

point of failure. This protection feature latches in the event
of over voltage across the output. Cycling the on/off pin or
input voltage resets the latching protection feature. If the
auto-restart option (4) is ordered, the module will
automatically restart upon an internally programmed time
elapsing.

Overcurrent Protection

To provide protection in a fault (output overload) condition,

the unit is equipped with internal
current-limiting circuitry and can endure current

limiting continuously. At the point of current-limit

inception, the unit enters hiccup mode. If the unit is
not configured with auto–restart, then it will latch off
following the over current condition. The module can be
restarted by cycling the dc input power for at least one
second or by toggling the remote on/off signal for at least
one second.

V

O

(+)

SENSE(+)

SENSE(–)

V

O

(–)

V

I

(+)

V

I

(-)

I

O

LOAD

CONTACT AND

DISTRIBUTION LOSSE

SUPPLY

I

I

CONTACT

RESISTANCE