Data Sheet

May 6, 2011

ESTW015A0F Series Eighth-Brick Power Modules

36

–75Vdc Input; 3.3Vdc Output; 15A Output

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute
stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those
given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can
adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

Continuous

All

V

IN

-0.3

80

V

dc

Transient, operational (

≤100 ms)

All

V

IN,trans

-0.3

100

V

dc

Operating Ambient Temperature

All

T

A

-40

85

°C

(see Thermal Considerations section)

Storage Temperature

All

T

stg

-55

125

°C

I/O Isolation voltage (100% factory Hi-Pot tested)

All

2250

V

dc

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

36

48

75

V

dc

Maximum Input Current

All

I

IN,max

2.0

A

dc

(V

IN

= V

IN, min

to V

IN, max

, I

O

=I

O, max

)

Input No Load Current

All

I

IN,No load

30

mA

(V

IN

= V

IN, nom

, I

O

= 0, module enabled)

Input Stand-by Current

All

I

IN,stand-by

6

8

mA

(V

IN

= V

IN, nom

, module disabled)

Inrush Transient

All

I

2

t

1

A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V

IN, min

to V

IN, max,

I

O

= I

Omax

; See Test configuration section)

All

30

mA

p-p

Input Ripple Rejection (120Hz)

All

50

dB

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information
provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating
can be used. Refer to the fuse manufacturer’s data sheet for further information.