Thermal considerations – GE Industrial Solutions ESTW015A0F Series User Manual

Page 9

Advertising
background image

Data Sheet

May 6, 2011

ESTW015A0F Series Eighth-Brick Power Modules

36

–75Vdc Input; 3.3Vdc Output; 15A Output

LINEAGE

POWER

9

Thermal Considerations

The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation.

Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel.

The thermal reference points, T

ref

x

used in the

specifications for open frame modules are shown in
Figure 13. For reliable operation T

ref

1

and T

ref

2

temperatures should not exceed 125

o

C and T

ref

3

temperature should not exceed 110

o

C.

Figure 13. T

ref

Temperature Measurement

Location for Open Frame Module.


Heat Transfer via Convection

Increased airflow over the module enhances the heat
transfer via convection. Derating curves, showing the
maximum output current that can be delivered by
the module versus local ambient temperature (T

A

)

for natural convection and up to 1m/s (200 ft./min)
forced airflow, are shown in Figure 14. Full power up
to T

A

=85

o

C, is achieved for airflow of 1 m/s(200 LFM)

or greater.

OU

TP

U

T

C

U

R

R

E

N

T

,

I

O

(

A

)

AMBIENT TEMEPERATURE, T

A

(

o

C

)

Figure 14. Output Current Derating for the Open
Frame Module; Airflow in the Transverse Direction
from Vout(+) to Vout(-); Vin =48V.



Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
the thermal aspects including maximum device
temperatures.

10

11

12

13

14

15

16

20

30

40

50

60

70

80

90

NC

0.5m/s

(100LFM)

1.0m/s

(200LFM)

Advertising