Feature specifications – GE Industrial Solutions ESTW015A0F Series User Manual

Page 4

Advertising
background image

Data Sheet

May 6, 2011

ESTW015A0F Series Eighth-Brick Power Modules

36

–75Vdc Input; 3.3Vdc Output; 15A Output

LINEAGE

POWER

4

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current (V

on/off

= -0.7 V

dc

)

All

I

on/off

0.15

mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

0.6

V

dc

Logic High Voltage (I

on/off

= 0A

dc

)

All

V

on/off

2.4

15.0

V

dc

Logic High maximum leakage current

All

I

on/off

25

μA

Turn-On Delay

1

and Rise Times

(I

O

=I

O, max ,

V

IN

=V

IN, nom,

T

A

= 25

o

C)

Case 1: Input power is applied for >1 second and then

the On/Off input is set to ON (T

delay

= time from instant

On/Off signal is ON until V

O

= 10% of V

O, set

)

All

T

delay

12

msec

Case 2: On/Off input is set to Logic Low (Module
ON) and then input power is applied (T

delay

= time

at which V

IN

= V

IN, min

until V

o

=10% of V

O,set

)

All

T

delay

20

msec

Output voltage Rise time (time for V

o

to rise from 10%

of V

o,set

to 90% of V

o, set

)

All

T

rise

4

msec

Output voltage overshoot

– Startup

All

5

% V

O, set

I

O

= I

O, max

; V

IN

=V

IN, min

to V

IN, max

, T

A

= 25

o

C

Remote Sense Range

All

V

SENSE

10

% V

O, set

Output Voltage Adjustment Range

All

-20

+10

% V

O, set

Output Overvoltage Protection (C

O

=220μF)

All

V

O, limit

3.9

5.0

V

dc

Overtemperature Protection

– Hiccup Auto Restart

All

T

ref

138

O

C

Input Undervoltage Lockout

All

V

UVLO

Turn-on Threshold

32

34.5

V

dc

Turn-off Threshold

27.5

30

V

dc

Hysteresis

1

2

V

dc

1. The module has an adaptable extended Turn-On Delay interval, T

delay

, of 25mS. The extended T

delay

will occur when the module restarts following

either: 1) the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout (which causes module shutdown), and then back
to normal; or 2) toggling the on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay interval, T

delay

,

will occur whenever a module restarts with input voltage removed from the module for the preceding 1 second.