Absolute maximum ratings, Electrical specifications, Gigatlynx – GE Industrial Solutions GigaTLynx User Manual

Page 2

Advertising
background image

Data Sheet
September 7, 2011

GigaTLynx

TM

SMT Non-isolated Power Modules:

4.5 – 14Vdc input; 0.7Vdc to 2.0Vdc, 50A Output

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

All

V

IN

-0.3 14 Vdc

Continuous

Sequencing pin voltage

All

Vs

EQ

-0.3 4 Vdc

Operating Ambient Temperature

All

T

A

-40 85 °C

(see Thermal Considerations section)

-D version

T

A

-40 105 °C

Storage Temperature

All

T

stg

-55 125 °C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

V

o,set

≤ 2.0

V

IN

4.5

14 Vdc

Maximum Input Current

All

I

IN,max

Adc

(V

IN

= V

IN, min

to V

IN, max

, I

O

=I

O, max

)

26

Inrush Transient

All

I

2

t

1

A

2

s

Input No Load Current

V

O,set

= 0.7Vdc

I

IN,No load

73.4 mA

(V

IN

= V

IN, nom

, Io = 0, module enabled)

V

O,set

= 1.8Vdc

I

IN,No load

136

mA

Input Stand-by Current

All

I

IN,stand-by

1.3

mA

(V

IN

= V

IN, nom

, module disabled)

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V

IN, min

to

V

IN, max,

I

O

= I

Omax

; See Test configuration section)

All

73

mAp-p

Input Ripple Rejection (120Hz)

All

50

dB

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included;
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a surface mount, fast acting fuse (ie. Littelfuse 456030 series) with a maximum rating of 30 A (see Safety
Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc
input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for
further information.