Car2548dc series dc-dc converters, Data sheet, Feature specifications (continued) – GE Industrial Solutions CAR2548DC series User Manual

Page 5: Digital interface specifications

Advertising
background image

GE

Data Sheet

CAR2548DC series dc-dc converters

Input: -36Vdc to -75Vdc; Output: 48Vdc @ 2500W; 3.3Vdc or 5 Vdc @ 1A

December 6, 2013

©2013 General Electric Company. All rights reserved.

Page 5

Feature Specifications (continued)

Parameter

Symbol

Min

Typ

Max

Unit

SMBAlert# (Interrupt) (Needs to be pulled HI via an external

i t )

Logic High (No Alert - normal)

I

OH

20 µA

V

OH

0.7V

DD

12 V

DC

Logic Low (Alert is set)

I

OL

20 mA

V

OL

0

0.4 V

DC

Output current monitor (Imon)

Resolution

100

mV/A

Accuracy

-5 5 %

of

FL

Measurement range

I

o

0 52

A

DC

Analog output range

V

mon

0 5.2

V

DC

Sourced output current

5 mA

DC


Digital Interface Specifications

Parameter

Conditions

Symbol

Min

Typ

Max

Unit

PMBus Signal Interface Characteristics
Input Logic High Voltage (CLK, DATA)

V

IH

2.1 3.6 V

DC

Input Logic Low Voltage (CLK, DATA)

V

IL

0 0.8 V

DC

Input high sourced current (CLK, DATA)

I

IH

0 10 μA

Output Low sink Voltage (CLK, DATA, SMBALERT#)

I

OUT

=3.5mA V

OL

0.4 V

DC

Output Low sink current (CLK, DATA, SMBALERT#)

I

OL

3.5

mA

Output High open drain leakage current
(CLK,DATA, SMBALERT#)

V

OUT

=3.6V I

OH

0 10 μA

PMBus Operating frequency range

Slave Mode

F

PMB

10 400 kHz

Measurement System Characteristics
Clock stretching

t

STRETCH

25 ms

I

OUT

measurement range

Linear

I

RNG

0 52 A

DC

I

OUT

measurement accuracy 25°C

I

ACC

-3

+3

% of FL

V

OUT

measurement range

Linear

V

OUT(rng)

0

60

V

DC

V

OUT

measurement accuracy

V

OUT(acc)

-3 +3 %

Temp measurement range

Linear

Temp

(rng)

0

120

C

Temp measurement accuracy

6

Temp

(acc)

-5 +5

C

I

IN

measurement range

Linear

I

IN(rng)

0 80 A

DC

I

IN

measurement accuracy

I

IN(acc)

-5 +5 %

V

IN

measurement range

Linear

V

IN(rng)

0

80 V

DC

V

IN

measurement accuracy

V

IN(acc)

-3 +3 %

P

IN

measurement range

Linear

P

N(rng)

0 3000 W

P

IN

measurement accuracy

P

IN(acc)

-5 +5 %

Fan Speed measurement range

Linear

0

30k

RPM

Fan Speed measurement accuracy

-5

5

%

Fan speed control range

-direct-

0

100

%

6

Temperature accuracy reduces non-linearly with decreasing temperature

Advertising